W
ELDING
R
ESULT
C
ONTROL
F
UNCTION
A
DMINISTRATOR
F
UNCTIONS
C
HAPTER
7
138
7.3.2
Details of welding control items
This section explains about details of the welding control items.
7.3.2.1
Number of welding point
The number of welding points is controlled according to the setting range.
•
Cumulative number of welding points
The interval from the start of current flowing triggered by the torch switch ON to the stop of output triggered by the
torch switch OFF is regarded as one count (one welding point) and accumulated.
The setting range of count value is between 0 and 999. The count value will be cleared according to the target value
achieved setting. (If continuous operation is enabled, the value will be cleared when exceeding 999 and return to 0.)
•
Target value of welding points
Select the target value of welding points in the range from 0 to 999. When the cumulative number of welding points
reaches the number of welding points specified here, an alarm appears indicating that the target is achieved.
(
-
Alarm indication when target is achieved)
•
Operation at the time when the target value of welding points is achieved
Select the operation from [
/×] mark for the time when the target specified for welding points is achieved. The set
values and operations when the target is achieved are as below.
7.3.2.2
Wire consumption
Wire consumption is controlled according to the setting range.
•
Cumulative wire consumption used in welding
Wire consumption (kg) used in welding is measured and counted.
The setting range of count value is between 0 and 999 kg. The count value will be cleared according to the target value
achieved setting.
(If continuous operation is enabled, the value will be cleared when exceeding 999 and returns to 0.)
T I P S
•
Approximate wire consumption will be obtained with the wire consumption control
function. The wire consumption may be different from the actual wire consumption due
to reasons such as slipping of wire.
The table below shows the wire unit amount (g/m) calculated from the specific gravity
(g/cm
3
) of the wire material. Wire consumption is calculated based on the unit amount
and the wire feeding amount during welding. Therefore, there will be differences
between the actual consumption and the calculated value depending on the wire
constituents.
•
When wire consumption is 100 kg or lower, the value after the decimal point is also
displayed.
•
The wire consumption used in inching or wire slowdown is not measured.
•
Special wires not listed in the table below are not measured.
Descrption
Enabled
Disabled
The count value is cleared when the target is achieved
(
*1
)
×
Welding is stopped when the target is achieved
(
*2
)
×
The Count value is cleared when the power is turned on
×
*1: When an alarm is displayed, selecting any item on the touch panel can also clear the count value.
*2: If "Disabled" is selected and the target is achieved, next welding cannot start until any item on the touch screen panel is
selected.
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...