6.8 Operation of Analog Remote Control (Optional)
This section explains the functions of knobs and buttons arranged for the analog remote controller (optional) as well as
their operation.
Since the setting at the analog remote control is preferred when connected, it is not possible to set this condition on the
touch panel of welding power source. (The start condition and crater condition can be set on the touch panel.)
T I P S
•
In connecting (or removing) the analog remote control to (or from) the welding power source,
turn OFF the power switch of the welding power source.
•
The analog remote control is automatically recognized after being connected to the analog
remote control and turning ON the power switch.
No.
Name
Function
1
Welding current adjustment knob
Set the welding current. The set value is displayed on the touch panel of the welding power source
side.
2
Welding voltage adjustment knob
Set the welding voltage. The set value is displayed on the touch panel of the welding power
source.
•
< Synergic: ON adjustment >
Optimum welding voltage according to the welding current is automatically set, and fine
adjustment is available for the set welding voltage.
Align the welding voltage adjustment knob to the center ("
●
" mark), and adjust the voltage
with the position as the standard.
•
< Synergic: OFF adjustment >
The welding voltage can be individually adjusted without being influenced by the welding
current.
3
Inching button
Feeds the wire. (
During when the button is pressed, the wire feeding is carried out.
Wire feed speed can be adjusted by the welding current adjustment knob while pressing the
inching button.
4
Scale plate (*1)
Replace the scale plate for analog remote control (
-
F9: Analog remote control scale)
when using the optional analog remote control. Note that the scale of analog remote control as
well as the scale plate to be used depends on the rated output current of the welding power
source. (Above diagram shows an example with 350 A)
•
350 A: 350/200
•
500 A: 500/350/200
5
Switch knob
Operated to use the functions selected in internal function F2. (
6
Fixing screw
To replace the scale plate, turn the screw counter clockwise, and remove them.
*1: For adjustment of low current region when using a thin wire, etc., using the accessory scale plate with full scale of 200 A allows
fine adjustment. To use this scale plates, set the internal function F9 function. (
-
F9: Analog remote control scale)
1
3
5
6
4
2
Содержание OTC ARXIS pulse P403L
Страница 1: ...July 2023 Manual No P30433 1 DAIHEN Corporation ARXIS pulse P403L P503L OWNER S MANUAL...
Страница 174: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 172 10 2 1 Schematic diagram ARXIS WB P403L...
Страница 175: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 173 Chapter 10 Reference Materials...
Страница 176: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 174 ARXIS WB P503L...
Страница 177: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 175 Chapter 10 Reference Materials...