* Set Delay Time (Delay Timer)

-

If pressing the SUB button in the Set Operation Timer Mode, it is switched to the Set Delay 
Time mode.

-

The Delay Timer sets the reservation time and has the function that sets so that the 
operation of Heating and Timer are performed after that time is elapsed.

                         

-

The proper use of the delay timer is to manipulate so that the reservation time is set for the 

first time, and then the temperature and the operation timer is set and the set operation is 

automatically operated after the reservation time is elapsed.

-

The  reservation  time  value  is  displayed  over  blinking  on  the  display,  and  if  pressing  the 

PUSH button by setting the reservation time value with the Jog-Dial knob, the value is fixed 

on the Display, and the reservation timer is activated.

-

After  setting  the  reservation  timer  value,  you  can  set-up  the  operation  timer  value  by 

pressing the MAIN button and then press Start button. And, you can set-up the temperature 

by  pressing  the  MAIN  button  again,  and  then  press  Start  button.  The  Start  button  in  the 

condition that the reservation timer has been set-up, is the button for the operation of the 

setting value after the reservation timer, not to immediately operate.

-

As described above, if continuously setting the operation, Heating and Timer are operated 

after the set reservation time as user intend.

-

Since  the  delay  timer  is  not  set  during  the  operation  of  Heating/Timer,  the  delay  timer 

should be set after stopping the operation of Heating/Timer.

-

You  can  change  or  save  the  setting  by  using  the  operation  method  of  the  Jog-Dial,  and 
Start/Stop of operation can be performed.

-

If pressing MAIN button, it is switched to the Set Operation Time Mode.

< Fig 3.3.2. Set Delay Time Mode>

DTim SV    :            00:00
DTim PV    :            00:00

Set Time

Remain Time

Timer LED (Green)

Содержание ThermoStable OF-105

Страница 1: ...Liability Insurance Patented No 10 0554098 Jog Shuttle Control System Validation IQ OQ Service User Manual Version2 2 1 written for ThermoStableTM OF 50 105 155 W105 W155 models ThermoStableTM OF 105...

Страница 2: ...DAIHAN Sci com or ALL forLAB com Shopping Mall DAIHAN Scientific Forced Convection type Oven 2 48...

Страница 3: ...Product Introduction 5 1 3 Product Configuration 6 2 Installation 2 1 Product Installation 7 2 2 Product Specifications 9 3 Product Usage 3 1 Product Usage 10 3 2 Names of Each Part 13 3 3 Usage Inst...

Страница 4: ...ing Warning Failure to follow the instructions may result in injury Caution Failure to follow the instructions may result in product failure Proximity Caution Keep clear of the product during use Noti...

Страница 5: ...utting the Air Flow Layer between the advanced insulator and the enclosure 6 The Chamber and inner shelf prevents corrosion by using Stainless Steel material 7 This product minimizes the heat loss by...

Страница 6: ...Liter ThermoStable OF 155 General Forced air Oven without Window 155Liter ThermoStable OF W105 General Forced air Oven Built in Viewing Window 105Liter ThermoStable OF W155 General Forced air Oven Bui...

Страница 7: ...mal operation at a rated voltage so please check the voltage status before installing the product 7 When installing and using the product please certainly use the power cord provided with the products...

Страница 8: ...ols stickers Attached to side of product For meaning of each symbol please refer to Precautions Before Use Safety Instructions Product Liability PL Insurance Admission DAIHAN Scientific Co Ltd is a me...

Страница 9: ...min to 150 6min to 100 6min to 150 Controller Digital Fuzzy Control by Advanced Microprocessor Jog Dial with Push Button RS232 Port Available to connect with PC Display Digital LCD with Back Light Tim...

Страница 10: ...distress the power cord Please do not hurt on the power cord or process it or force bend it or pull it and tie it Also if heavy objects are placed over the power cord or the power cord is inserted in...

Страница 11: ...hines and can get rained on it is prohibited It may cause overheating or electrical fault of the product Please do not use flammable or volatile products in the vicinity of the product to minimize the...

Страница 12: ...d please contact the deliverer or our technical service engineer Do not operate the unit before checking with an engineer otherwise it may cause an electrical shock or a fire The Sound Level of the bu...

Страница 13: ...tableTM OF 105 155 W105 W155 2ea Controller Set and Check operation Window Safety Double Door Handle Door open and close Fig 3 2 3 Back of ThermoStableTM OF 105 155 ThermoStableTM OF W105 W155 Fig 3 2...

Страница 14: ...OFF Fuse Protect unit from High Current Safety Switch Prevent overheat RS232 connection Serial Interface for Remote control by PC Fig 3 2 5 Standard Model ThermoStableTM OF 105 Fig 3 2 6 Side of Ther...

Страница 15: ...ation of TIMER HEAT ERROR REF MAIN Button Convert into mode of Timer Heating Locking SUB Button Convert into mode of delay timer and offset function Jog shuttle knob Control that Reduces or Adds Value...

Страница 16: ...it can be adjusted by the Jog Dial knob after stopping the product by pressing briefly once the PUSH button If pressing for 2 or 3 seconds the PUSH button the set value is saved and even if the power...

Страница 17: ...d the reservation timer is activated After setting the reservation timer value you can set up the operation timer value by pressing the MAIN button and then press Start button And you can set up the t...

Страница 18: ...ndicates the standby status while blinking in long interval The range of the setting temperature is adjustable in the unit of 1 and can be set up to 230 You can change or save the setting by using the...

Страница 19: ...king If pressing MAIN button in the Set Temperature Mode it is switched to the Locking mode In the Locking Mode the Turning by the Jog Dial Knob or Push button do not applied and LCD Display and LED l...

Страница 20: ...1050 Validation Service lQ OQ OFV1050 for ThermoStable OF 50 DH WOF31105 Validation Service lQ OQ OFV1105 for ThermoStable OF 105 DH WOF31155 Validation Service lQ OQ OFV1155 for ThermoStable OF 155 D...

Страница 21: ...t and soft cloth is recommended Do not use coarse cloth strong chemicals or organic solutions 3 Do not use water Benzene Thinner or any alcohol for cleaning the product It may cause discoloration dama...

Страница 22: ...f current temperature of product when slowly turning clockwise up to 320 after adjusting the Safety Knob to 0 4 Tak sound is Normal If Tak sound is not occurred A S is required 5 Please check the prog...

Страница 23: ...ted Heating but temperature is fluctuated Check the temperature that is currently set Make sure that the power switch is in the ON position Check that SAFETY Knob is not placed in the 0 position and i...

Страница 24: ...ument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This certification is only for international cu...

Отзывы: