background image

 

24

ADDR       

 001-H 

BAUD RATE 

9600 

PARITY     

NONE 

PROTOCOL   

PELCO-D 

MODEL     

SD6663-HN 

TEMP                : 032

 

SOFTW ARE   

v1.04.3 

BACK 
EXIT 

 

FACTORY DEFAULT: Restore dome factory default setup. Please move the cursor to the option and 

then click confirm button until you see O.K. Now you can see the IP dome begin rebooting to restore 

factory default setup. 

 

RESTART: Reboot the speed dome. 

 

BACK: Go back to the previous menu. 

 

EXIT: Log out system menu. 

4.4.1.1

 

 

Initialization information  

 
 
 
 
 
 
 

 
 

Move the cursor to INITIAL INFORMATION and then click confirm button, you can see the above interface.  
Here you can view dome basic information.  

4.4.1.2

  Address Information 

 
 
 

 

Move the cursor to SITE INFORMATION and then click confirm button. 

 

ADDR TYPE: There are two options: soft and hard. Please use the left/right button on the keyboard or 

in the speed dome terminal menu to set.    

 

ADDR-HARD:  It is an address you set in the dial switch. You can not modify it through software.  

 

ADDR-SOFT: You can set address via software. It is to say, you can use menu to modify dome address. 

The value ranges from 1 to 255. 

 

BACK: Go back to the previous menu. 

 

EXIT: Log out system menu. 

4.4.1.3

 System Time Setting 

 
 
 
 
 
 
 

 

Move the cursor to SYSTEM TIME SETING and then click confirm button, you can go to the third 

submenu. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. 

After completed setup, please click confirm button to save current setup.  After you see speed dome 

menu displays OK, you can see the setup is valid now. 

 

4.4.2  Display Setting 

 
 
 

ADDR TYPE      : HARD      
ADDR-HARD      : 001 
ADDR-SOFT      : 001 
BACK 
EXIT 

 

YEAR       : 2009 
MONTH    : 001 
DATE       : 017 
WEEK       : SUNDAY         
HOUR       : 013 
MINU

     : 052 

SAVE 
BACK 
EXIT 

Содержание SD6980-HN

Страница 1: ...IR Speed Dome User s Manual Version 1 1 ...

Страница 2: ...Auto Flip 9 1 2 13 Self diagnosis 9 1 2 14 Day Night Mode B W Color Mode 9 1 2 15 Auto Focus 9 1 2 16 Backlight Compensation 10 1 2 17 Pan Tilt and Zoom 10 1 2 18 3D Intelligent Location 10 1 2 19 Idle Status 10 1 2 20 Image Flip 10 1 3 1 3 1 3 1 3 Specifications Specifications Specifications Specifications 10 1 3 1 Performance Specifications 10 1 3 2 Technical Specifications 11 2 2 2 2 PROTOCOL B...

Страница 3: ...22 4 3 4 3 4 3 4 3 Main Menu Main Menu Main Menu Main Menu 22 4 4 Menu Operation 23 4 4 1 System Information 23 4 4 2 Display Setting 24 4 4 3 Camera Setting 25 4 4 4 Function Setting 28 4 4 5 IR Light Setup 34 4 4 6 Alarm Setup 35 4 5 Dome Abnormal Phenomenon Operation 36 4 5 1 Restore to Factory Default Setup 36 4 5 2 PTZ Movement is not smooth 36 5 5 5 5 FAQ FAQ FAQ FAQ 37 5 1 Daily Maintenance...

Страница 4: ...s and Terminal Resistance Connection Methods and Terminal Resistance Connection Methods and Terminal Resistance 39 7 4 7 4 7 4 7 4 The Problem in Practical Use The Problem in Practical Use The Problem in Practical Use The Problem in Practical Use 39 7 5 7 5 7 5 7 5 RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ 40 8 8 8 8 APPENDIX TOXIC OR HA APPENDIX TOXIC OR HA APPENDIX TOXIC OR HA APPE...

Страница 5: ...eference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Before installation and operation please read the following safeguards and warnings carefully ...

Страница 6: ...ances and etc The working temperature ranges from 30 60 Outdoor Please keep it away from the electromagnetic radiation object and environment Please keep the sound ventilation Do not allow the water and other liquid falling into the device Please make sure the CCD CMOS component is out of the radiation of the laser beam device Otherwise it may result in CCD CMOS optical component damage 5 Daily Ma...

Страница 7: ...use all the accessories recommended by manufacturer Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if something is missing in your package ...

Страница 8: ...nd suburb 1 2 1 2 1 2 1 2 F F F Feature eature eature eatures s s s This series speed dome has the following features 1 2 1 On Screen Menu This series product menu supports multiple languages display and switch It is easy for you to view dome information and configure dome camera parameters 1 2 2 On screen Tips Here you can view Preset name and system version Software and hardware Dome system temp...

Страница 9: ...ree alarm activation operations There are 7 alarm inputs NO NC Alarms can be individually programmed to initiate an associated preset scanning or tour when received Dome will return to a previously programmed state after alarm acknowledgement or to its previous position before alarm 1 2 12 Auto Flip As long as you continue to hold the keyboard joystick in the down position the dome rotates 180 deg...

Страница 10: ...ivid image 1 2 18 3D Intelligent Location Working with DVR just click part of the current scene will be displayed in the central window and automatically zooms All of these allow you to trace precisely 1 2 19 Idle Status When there is no available order you can use menu to set dome idle status after specified duration The idle status includes turn to specified preset or go to scan tour or pattern ...

Страница 11: ...ure Elegant mechanical driver device Support 360 degrees continuous rotation no monitor blind spot 0 1 s rotation speed while maintain stable image 180 degrees tilt continuous monitor Built in IR light Support zoom level has the higher priority default manual or the height has the higher priority In the night vision status it can use the IR light to spot the monitor object or you can monitor the e...

Страница 12: ...in accordance with lens Auto Rotation Tilt 92º auto rotates to pan 180 º Auto Pan 0 º 360º continuously Manual Pan Motion Speed 0 1º 200º S Preset Maximum Speed 60 º 240º s There are 16 level You can set from the menu Manual Tilt Motion 0 1º 120º S Manual Tilt Scan Section 0º 180º Control Port RS485 BUS Baud Rate 1200 2400 4800 9600 Optional PTZ Scan Accuracy 0 06 0 015º Signal Format PAL NTSC Cam...

Страница 13: ... can not control the product 2 1 2 1 2 1 2 1 Protocol and Protocol and Protocol and Protocol and B B B Baud aud aud aud R R R Rate ate ate ate S S S Setup etup etup etup Please configure the following settings before begin controlling dome Protocol Baud rate Address Note Please reboot the speed dome to get all the setups activated Open the lower dome the interface is shown as below See Figure 2 1 ...

Страница 14: ...l ON OFF OFF PELCO D OFF ON OFF PELCO P X X X Reserved Please refer to the baud rate sheet for detailed information 4 5 Baud Rate OFF OFF 9600bps ON OFF 4800bps OFF ON 2400bps ON ON 1200bps Please refer to the parity setup sheet for detailed information 6 7 Parity OFF OFF NONE ON OFF EVEN OFF ON ODD ON ON NONE 2 2 2 2 2 2 2 2 Set address dial switch Set address dial switch Set address dial switch ...

Страница 15: ... OFF OFF OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF OFF OFF 3 ON ON OFF OFF OFF OFF OFF OFF 4 OFF OFF ON OFF OFF OFF OFF OFF 5 ON OFF ON OFF OFF OFF OFF OFF 6 OFF ON ON OFF OFF OFF OFF OFF 7 ON ON ON OFF OFF OFF OFF OFF 8 OFF OFF OFF ON OFF OFF OFF OFF 254 OFF ON ON ON ON ON ON ON 255 ON ON ON ON ON ON ON ON ...

Страница 16: ...al and power connection Please connect the power cable to the power socket of the speed dome connect the RS485 cable to the RS485 port of the speed dome See Figure 3 1 and Figure 3 2 Figure 3 1 Figure 3 2 Name Function 485 A 485 A It is to control dome built in PTZ B 485 B It is to control dome built in PTZ GND Ground AUDIO OUT Reserved audio port Audio output port Right now the device does not su...

Страница 17: ...me Function Alarm out 1 2 Two alarm output channels When there is an alarm from current channel system activates relay or not Alarm output relay default setup is NO You can use the jump cap near the power board relay to set NO Normal open alarm output NC Normal close alarm output GND Alarm input ground end Alarm in 1 7 Seven alarm input channels It is to receive relay signal from the external alar...

Страница 18: ...nd normal close 3 2 1 System Layout 3 2 1 1 BUS connection Please refer to Figure 3 5 and Figure 3 6 for BUS cable connection Figure 3 5 Figure 3 6 Note Please use shielded twisted pair The shielded layer shall connect to GND firmly otherwise it may affect communication or video work 3 2 1 2 Star Connection Please refer to Figure 3 7 for start connection information ...

Страница 19: ...on This series dome supports keyboard operation You can use keyboard to control the dome and PTZ The display and control can work simultaneously One keyboard can control maximum 255 speed domes Please refer to Figure 3 9 Figure 3 9 This IR speed dome protocol is open and supports multiple popular system platforms in today s market ...

Страница 20: ...f some matrix systems do not support dome camera communication protocol The most direct and easy way is to use current system to process video signal and add some control keyboards to control speed dome See Figure 3 10 Figure 3 10 ...

Страница 21: ...M INFORMATION CAMERA SETTING FUNCTION SETTING ALARM SETTING WB SETTING EXPOSURE SETTING DAY NIGHT SETTING FOCUS MODE AUTO FOCUS LIMT 30CM ZOOM SPEED 08 DIGITAL ZOOM OFF APERTURE 06 NEXT PAGE BACK EXIT PRESET AUTO PAN AUTO SCAN AUTO CRUISE AUTO PATTERN IDLE MOTION TIME TASK AUTO RUN PRIVACY MASKING NEXT PAGE BACK EXIT ALARM NO 01 ACTION NONE CONTACT N O PRESET 001 AUTO SCAN 001 CRUISE 001 RELAY OUT...

Страница 22: ...gnosis system pops up error code The above interface disappears after speed dome received the first command or the display time lasts for 4 minutes ADDR Here you can view dome address information For example 001 H 1 is the address number H is hard address mode S is software address mode Baud rate Dome communication baud rate Parity Communication parity bit format Protocol Current communication pro...

Страница 23: ... click confirm button to go back to the previous menu Use up down button to select exit option and then click confirm button to log out system menu All setup here will not lose when encounter power failure 4 4 1 System Information INITIAL INFORMATION Move the cursor to INITIAL INFORMATION and then click confirm button to go to the third submenu ADDR INFORMATION Move the cursor to SITE INFORMATION ...

Страница 24: ...options soft and hard Please use the left right button on the keyboard or in the speed dome terminal menu to set ADDR HARD It is an address you set in the dial switch You can not modify it through software ADDR SOFT You can set address via software It is to say you can use menu to modify dome address The value ranges from 1 to 255 BACK Go back to the previous menu EXIT Log out system menu 4 4 1 3 ...

Страница 25: ...menu to set INSIDE TEMPERATURE Display dome internal temperature or not There are three options F Off Please use the left right button on the keyboard or in the speed dome terminal menu to set OUTSIDE TEMPERATURE AND HUMIDITY Display dome external temperature and humidity There are three options F Off Please use the left right button on the keyboard or in the speed dome terminal menu to set IDLE T...

Страница 26: ...us menu EXIT Log out system menu 4 4 3 1 White Balance Setup Move the cursor to WHITE BALANCE MODE and then click confirm button you can go to the submenu WHITE BALANCE MODE Set white balance adjustment mode There are two modes auto manual Please use the left right button on the keyboard or in the speed dome terminal menu to set R GAIN Before you set R GAIN option please note the mode shall not be...

Страница 27: ...Please make sure your camera supports this function SLOW SHUTTER In lower illumination environment you can lower the cameras auto exposure time to capture the image and enhance the definition Please note for the moving object the image trail phenomenon may occur Please use the left right button on the keyboard or in the speed dome terminal menu to set BLC It is an abbreviation for back light compe...

Страница 28: ...o the submenu PICTURE FLIP This function allows you to turn the image rotation 180 degrees There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to set FREEZE FUNCTION This function allows the system from one preset to another preset without showing the video during the PTZ movement There are two options on off Please use the left right bu...

Страница 29: ...op up a message PRESET Here means preset number And the SETTING column pops up an OK Now you successfully added a preset Please note you need to enable display preset title function first Main menu display setting preset title Repeat the above procedures to set more presets Once you want to modify a preset you can input the preset number you want to modify and then follow the above steps to set th...

Страница 30: ...the keyboard or in the speed dome terminal menu to set SET LEFT LIMIT Here is to set camera left address Click confirm button to save current setup SET RIGHT LIMIT Here is to set camera right address Click confirm button to save current setup SCAN SPEED The value ranges from 1 to 255 Please use the left right button on the keyboard or in the speed dome terminal menu to set RUN Please input auto sc...

Страница 31: ...tup After you completed the setup move the cursor to back button to go to the previous interface DELETE CRUISE Here is to delete a cruise Input cruise number in CRUISE NO and then move the cursor to DELETE cruise click confirm button to delete CALL Here is to activate cruise Input touring number in touring NO and highlight CALL click confirm button to activate touring STOP Here is to terminate tou...

Страница 32: ...sk setup interface For SONY series cameras There are maximum 8 privacy mask zones in 360 degrees The tilt angle ranges from 0 to 70 degrees For HITACHI series cameras There are maximum 8 privacy mask zones in 360 degrees System supports two privacy zones in one screen Tilt angle ranges from 0 to 45 degrees Note For security reasons please set privacy zone a little bit larger than the privacy objec...

Страница 33: ...ly goes on the previous set functions IDLE FUNCTION There are two modes ON OFF Please use left right key to set IDLE TIME System idle period The value ranges from 1 to 720 minutes Please use the left right button on the keyboard or in the speed dome terminal menu to set IDLE ACTION There are several functions you can select NONE PRESET SCAN TOURING PATTERN Please use the left right button on the k...

Страница 34: ...se use the up down button to set the detail value and then use left right button to go to the next setup item After you completed the setup please click confirm button to exit end time setup and then move the cursor to the SAVE button to save current setup TASK ACTION The option here includes none tour scan preset patter Please use left right button to set PRESET The speed dome will go to the sele...

Страница 35: ...open N O and normal closed N C Please use the left right button on the keyboard or in the speed dome terminal menu to set PRESET NO Please use the left right button on the keyboard or in the speed dome terminal menu to set The camera will turn to the specified preset to monitor after alarm occurs AUTO SCAN Please use the left right button on the keyboard or in the speed dome terminal menu to set T...

Страница 36: ...INFORMATION move cursor to FACTORY DEFAULT and click confirm button Dome will reboot and all the setups restore to factory default setup 4 5 2 PTZ Movement is not smooth From menu to SYSTEM INFORMATION move cursor to RESTART and click confirm button This reboot will not modify all activated setup such as preset tour and pattern ...

Страница 37: ...ower socket Mechanical malfunction Need electrical engineer help Self diagnosis is ok No video signal Power connection is too loose connect tightly Check the circuit connection Connect again Video switch connection is wrong or improper operation Please refer to user s manual for cable connection information Self diagnosis is o k but I can not operate the dome Control circuit is not properly connec...

Страница 38: ...aling steel tube under the land to implement cable layout and connects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shal...

Страница 39: ...agnetic interference There are too much devices connected to the RS485 bus And vice versa the max transmission distance shall become longer 7 3 7 3 7 3 7 3 Connection Connection Connection Connection Methods and Terminal R Methods and Terminal R Methods and Terminal R Methods and Terminal Resistance esistance esistance esistance 1 RS485 bus requires all devices use the following connection methods...

Страница 40: ... 7 5 7 5 7 5 RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ RS485 Bus FAQ Phenomenon Possible Reasons Solution Speed dome can run self diagnosis but I can not control it Host address baud rate and speed dome address baud rate are not match Positive and negative end of RS485 Bus are misconnected Connection cable is loose RS485 Bus connection are cut off Modify host or speed dome setup Switch RS485 posit...

Страница 41: ...ration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ T11363 2006 standard X Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard Note This manual is for reference only Slight difference may be found in the u...

Отзывы: