![Dahua NVR41-P series Скачать руководство пользователя страница 156](http://html1.mh-extra.com/html/dahua/nvr41-p-series/nvr41-p-series_user-manual_4168844156.webp)
Local Basic Operation 145
Figure 4-83
Step 2 Configure parameters. See Table 4-20.
Table 4-20
Parameter
Description
Channel
In the
Channel
list, select the channel that you want to connect the PTZ
camera to.
PTZ Type
Local: Connect through RS-485 port.
Remote: Connect through network by adding IP address of PTZ
camera to the Device.
Protocol
In the
Protocol
list, select the protocol for the PTZ camera such as
PELCOD.
Address
In the
Address
box, enter the address for PTZ camera. The default is 1.
The entered address must be the same with the address configured on
the PTZ camera; otherwise the system cannot control PTZ camera.
Baud rate
In the
Baud rate
list, select the baud rate for the PTZ camera. The default
is 9600.
Data Bits
The default is 8.
Stop Bits
The default is 1.
Parity
The default is NONE.
Step 3 Click
Apply.
4.4.2
PTZ Control
PTZ control panel performs the operations such as directing camera in eight directions,
Содержание NVR41-P series
Страница 1: ...Network Video Recorder User s Manual V4 4 6 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...
Страница 81: ...Device Installation 70 3 6 12 NVR42V 8P Series Please refer to Figure 3 12 for connection sample Figure 3 12...
Страница 255: ...Local Basic Operation 244 Figure 4 178...
Страница 256: ...Local Basic Operation 245 Figure 4 179...
Страница 361: ...Compatible Network Camera List 350 Website www dahuasecurity com...