Web Operations
148
Select
SETUP > SYSTEM > PTZ
.
Step 1
The
PTZ
interface is displayed.
Select a channel.
Step 2
In the
PTZ Type
list, select PTZ type, and then configure other parameters.
Step 3
If Channel 1 to Channel 8 is selected, the PTZ type is
Local
by default which
cannot be modified. See Figure 5-28. Configure the parameters. For details, see
PTZ settings (Local)
Figure 5-28
Table 5-9 PTZ settings parameter parameters description
Parameter
Description
Channel
Select a channel that is connected to PTZ camera.
Protocol
Select the protocol that matches the PTZ camera.
Address
Enter the address for PTZ camera.
The entered address must be the same with the address configured on
the PTZ camera; otherwise the PTZ camera cannot be controlled from
the Device.
Baud Rate
Select the baud rate for the PTZ camera.
Data Bit
The default value is 8.
Stop Bit
The default value is 1.
Parity
The default value is None.
If Channel 9 to Channel 12 is selected, in the
PTZ Type
list, select
Remote
. See
PTZ settings (Remote)
Figure 5-29
Click
Save
.
Step 4
Click
Copy
to copy the settings to other channels.