Dahua ITC237-PU1B-IR Скачать руководство пользователя страница 30

                                                                           

 

 

24 

Set snap OSD information and location, OSD options include time, driveways name, week, location, 

speed, license plate, illegal code and other information.  

 

Select Setup>ITC>OST Config>Snap PSD. See 

Figure 4-9

. 

 

Figure 4-9

 

 

Select any region in video, and drag mouse to add snapshot title. Move box to place you want to 

display it, or enter coordinate value in X/Y field on the right.  

The system supports up to 8 snapshot titles, and each snapshot can customize OSD.  

Note: 

Select a snapshot, right click to delete current snapshot title.  

 

Select OSD black border position, including top, bottom or none.  

 

Set OSD info font size and font plan. At the lower right corner, you can set snapshot OSD info font 

color.  

 

Click More, to pop up new line and OSD separator. According to actual need, check new line, and 

set OSD info separator. 

Select custom, to manually enter other separator.  

Содержание ITC237-PU1B-IR

Страница 1: ...2 0MP CMOS HD Camera Web Operation Manual Version 1 0 1 ...

Страница 2: ...tion Please install the proper power cut off device during the installation connection in case there is any emergency situation Always follow the instruction guide the manufacturer recommended 4 Qualified engineers needed All the examination and repair work should be done by the qualified service engineers We are not liable for any problems caused by unauthorized modifications or attempted repair ...

Страница 3: ...n in your package 7 Daily Maintenance Please shut down the device and then unplug the power cable before you begin daily maintenance work Use the dry soft cloth to clean the device If there is too much dust please use the water to dilute the mild detergent first and then use it to clean the device Finally use the dry cloth to clean the device ...

Страница 4: ...d software here are subject to change without prior written notice All trademarks and registered trademarks mentioned are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local retailer for more information ...

Страница 5: ... 3 1 2 Picture Attribute 13 3 1 3 PC Picture 13 3 2 Record Query 14 3 2 1 Record 14 3 2 2 Water Mark 15 3 3 Plate Query 16 4 Configure 18 4 1 ITC 18 4 1 1 Guide Setup 18 4 1 2 Snapshot 19 4 1 3 Intelligence 21 4 1 4 OSD Config 22 4 1 5 Extra Device 25 4 1 6 Plate White Black List 26 4 1 7 Intelligence Default 31 4 2 Camera 31 4 2 1 Attribute 31 4 2 2 Video 34 4 3 Network 37 4 3 1 TCP IP 37 4 3 2 O...

Страница 6: ...TP 44 4 5 4 Client 45 4 5 5 Path 46 4 6 System 47 4 6 1 General 47 4 6 2 Account 49 4 6 3 Default 52 4 6 4 Import Export 53 4 6 5 Auto Maintain 53 4 6 6 Upgrade 54 4 7 Information 54 4 7 1 Version 54 4 7 2 Log 55 4 7 3 Online User 56 5 Alarm 57 6 Logout 58 ...

Страница 7: ...a IP address in the address column For example if your IP is 192 168 1 108 then please input http 192 168 1 108 in IE address column See Figure 1 1 IE Figure 1 1 IE System pops up warning information to ask you whether install webrec cab control or not Please click yes button If you can t download the ActiveX file please modify your settings as follows See Figure 1 2 Input your IP address here ...

Страница 8: ...1 3 Please input your user name and password Follow system instructions to change password and click OK Default factory name is admin and password is admin Note For security reasons please modify your password after you first login You can go to Setup System Account User Name to change password ...

Страница 9: ...igure 1 3 Login Interface After you logged in HD intelligent traffic camera web homepage is shown as in Figure 1 4 Note Download and install plug in if you cannot enter the homepage Figure 1 4 Web Homepage ...

Страница 10: ...nd image set client image parameter Query Query image and record in different types watermark and vehicle pass record Setup Set ITC rule camera attributed network event storage system and view system info Alarm Set alarm prompt Logout Logout WEB client Table 1 1 The followings are common buttons you may see on WEB See Table 1 2 Button Note Click this button and click OK to restore system default s...

Страница 11: ...ere are five sections Section 1 Video bit stream bar Section 2 Preview window switch Section 3 Common function bar Section 4 System menu Section 5 Monitor window switch 2 1 Video Bit Stream Bar T he video bit stream bar interface is shown as in Figure 2 2 Figure 2 2 Video Bit Stream Bar Please refer to the following sheet for detailed information ...

Страница 12: ...rotocol Select video monitoring protocol currently support TCP only Fluency Select image fluency 2 2 Preview Window Switch The preview window switch interface is shown as in Figure 2 3 Preview Window Switch Figure 2 3 Preview Window Switch Aspect ratio adjust image to original size or best fit Window switch to large window and display adjusting window See Figure 2 8 is full screen button Te exit f...

Страница 13: ... Note Original size Original size and best bit size switch Click to switch to original size Image adjustment Display image adjustment window Click to then off image adjustment Table 2 1 Click on the right See Figure 2 5 Adjusting Window ...

Страница 14: ...gure 2 6 Common Function Bar Please refer to the following sheet for detailed information Icon Name Note Record Type Select record file format default is dav Receive Pictures Check this option system will auto records snapshots RS485 RS232 video detection and others trigger snapshot while recording plate vehicle color speed and other info will shown below Manually Snapshot Click it to snapshot vid...

Страница 15: ...ick to enter installation interface Figure 2 7 Steps to debug Step 1 Set focus zoom mode used to identify vehicle See Table 2 3 Parameter Note Auto Focus Auto adjust focus Note This function is for ITC237 PU1B IR ITC237 PU1B L camera only Auto adjust lens Note This function is for ITC237 PW1B IRZ camera ...

Страница 16: ...ll settings to default Pause Resume Resume When you click Pause Video pauses then click Resume to continue playing When you click Resume Video continue playing then click Resume to pause Refresh View latest status Table 2 3 Step 2 Select line type to configure See Table 2 4 Parameter Note Region Set region to delete Region is within red line Detect Line Draw detect line of trigger of snapshot Dete...

Страница 17: ...o Analysis Recognition Step 5 Set local plate Step 6 Click Save 2 4 Monitor Window Switch The monitor window switch interface is shown as in Figure 2 8 Monitor Window Switch Figure 2 8 Monitor Window Switch View pixel in pane Display in single window Display in four windows Display in full screen ...

Страница 18: ...e Query all pictures or filter picture by event type Plate Check this plate and filter picture by plate feature Click this button to download link record Note After link video is enabled all violation pictures have this icon However whether there is record depends on actual condition Table 3 1 Step 1 Enter parameter of query picture click Search In file list it shows all matched picture files Step...

Страница 19: ...ownloaded on PC picture attribute time is device end time Download Mode Selected file Select picture you need select one or more pictures as batch download click Download system pops up box Selected time Directly click Download system starts to auto download all pictures within start time and end time Reset Reset download picture naming to default method Help View naming rule of download picture T...

Страница 20: ...ou want to verify Step 2 Select picture Step 3 Click Water Verify see results in list You can click Open or double click picture to preview 3 2 Record Query 3 2 1 Record Click Query Record Query Record you can see an interface is shown as in Figure 3 4 Record Query ...

Страница 21: ...atus When it shows means it is playing record After you click it pause record Stop Click this button stop play Next Frame Click this button go to next frame Slow Click this button to slowly play Fast Click this button to fast play Table 3 3 3 2 2 Water Mark Note Before user can use this function he she must enable water mark in Setup Camera Video and set watermark content Default watermark is Digi...

Страница 22: ...igure 3 5 Step 1 Click Open Record select record file Step 2 Click Water Verify When it is complete the page will show complete 3 3 Plate Query Select Query Plate Query Plate Query search vehicle pass record Warning This function is valid for camera with TF card Figure 3 6 Step 1 Set query start time and end time ...

Страница 23: ...17 Step 2 Click Query see result in list Step 3 Click Export and select storage path to export result to PC ...

Страница 24: ...and default gateway Figure 4 1 Step 1 Click Setup Figure 4 2 Step 2 Set camera time date click Next Parameter Note Date Format Select date format to display Time Format Select time format to display Current Time Display device current time Sync PC Modify device system time to be current PC time click Sync PC It auto saves ...

Страница 25: ...IP address is 192 169 1 108 initial subnet mask is 255 255 255 0 initial gateway is 192 168 1 1 Time info can be modified in Setup System General Date Time IP address can be modified in Setup Network TCP IP 4 1 2 Snapshot 4 1 2 1 Snapshot The snapshot interface is shown as in Figure 4 4 Snapshot ...

Страница 26: ... snapshot incoming vehicle Reverse snapshot outgoing vehicle Double snapshot both incoming and outgoing vehicle Table 4 2 4 1 2 2 RS485 IO The intelligence default interface is shown as in Figure 3 4 Figure 4 5 RS485 IO Step 1 Check Start Coil IO Step 2 Select coil 1 trigger mode No trigger not trigger snapshot Rise edge trigger snapshot when vehicle exits coil Drop edge trigger snapshot when vehi...

Страница 27: ...nce Please refer to the following sheet for log parameter information Parameter Function Vehicle Sign Select this parameter it can recognize vehicle LOGO Vehicle Type Detect vehicle size Plate Size Set plate Min Height Max Height Min Width Max Width while only Min Width and Max Width are available for use Image Enhance Optimize plate effect Unlicensed motor category Select this parameter to snapsh...

Страница 28: ... confidence filter the less the criteria will be so the easier to recognize plate but miss alarm rate will be higher The higher the confidence filter the more the criteria will be so the harder to recognize plate but miss alarm rate will be lower Advance Options Enter custom advance options Table 4 3 Step 4 Click Save 4 1 4 OSD Config 4 1 4 1 Video OSD Set video channel OSD Step 1 Select Setup ITC...

Страница 29: ...oint coordinates select the channel position title e Click Save Step 4 Set time title and position f Select time title g Check Turn on h Check week i Use the mouse to drag the yellow box or change the regional point coordinates select the time the title of the position j Click Save Step 5 You can click to add customized region define OSD info The system supports up to 3 customized regions Step 6 C...

Страница 30: ...nter coordinate value in X Y field on the right The system supports up to 8 snapshot titles and each snapshot can customize OSD Note Select a snapshot right click to delete current snapshot title Select OSD black border position including top bottom or none Set OSD info font size and font plan At the lower right corner you can set snapshot OSD info font color Click More to pop up new line and OSD ...

Страница 31: ...odify any OSD options prefix suffix and other content and the number of separators Delete All selected OSD information state by turns you can delete any OSD options Remove All Clear all selected OSD information New Line OSD information will be displayed on the picture branches Table 4 4 Click Save 4 1 5 Extra Device Note This setup option is not for ITC237 PW1B IRZ Light 485 Config Set external li...

Страница 32: ... are 3 groups for selection Auto Mode When work mode is auto select NO light time and brightness Time set NO light period You can set 7 days in a week independently with six periods per day Brightness set preset brightness range 0 100 Note This function is for ITC237 PU1B L only Table 4 5 Click Time to set time 4 1 6 Plate White Black List 4 1 6 1 White List Select Setup ITC BW List Enable white l...

Страница 33: ...number which already exists in the white list data Card Word The checked characters are matched and unselected characters will not be analyzed Min Word When the number of matched characters meets the value it is regarded as white list vehicle regardless of whether other characters match or not Table 4 6 4 1 6 2 White List Search Search whether a plate of vehicle exits in white list View vehicle de...

Страница 34: ...28 Figure 4 13 Functions Search plate no Edit plate info Delete single plate no Batch delete plate no Progressively import white list info Steps Step 1 Click Add See Figure 4 14 ...

Страница 35: ...h import white list Steps Step 1 Progressively import white list add the first while data on WEB Step 2 Click Export and in pop up box click Save select path Click Save Step 3 In Export form follow format of the first white list item fill in other white list items you want to import save Step 4 Click Brose select path click Import Batch export white list click Export in pop up box click Save Selec...

Страница 36: ...ehicle info Figure 4 15 Please refer to Ch 4 1 6 2 4 1 6 4 Link Sign Out Enable link signal output Set open barrier mode Set alarm output of open barrier and close barrier Figure 4 16 Parameter Note Enable After check enable gateway control and config ...

Страница 37: ...ig close config Alarm output start alarm linkage output port you can choose any of the two ports Note For ITC237 PU1B IR ITC237 PU1B L only Output delay the duration of the opening or closing signal Table 4 7 4 1 7 Intelligence Default The intelligence default interface is shown as in Figure 4 17 Intelligence Default Click on default to restore default settings Note You cannot restore IP address a...

Страница 38: ...e When contrast is insufficient you may adjust this value Recommended value is 40 60 within 0 100 range Hue The value adjusts hue of image Default value is 50 It will not affect image brightness It has a relatively fixed value according to the sensor Recommended value is 40 60 within 0 100 range Saturation The value adjusts saturation of image Default value is 50 The higher the value the deeper th...

Страница 39: ...o the focal length of the lens SmartIR In SmartIR mode you can dynamically adjust the camera s infrared light intensity reduce the camera in the night vision environment close range objects produced over exposure phenomenon Off Turn off the fill light mode Note IR light is for ITC237 PW1B IRZ camera only IR light is unavailable under color mode 4 2 1 2 Shutter The shutter interface is shown as in ...

Страница 40: ...hted areas increases the brightness of low light areas and makes areas of highlights and low light areas clearer The larger the value the higher the wide dynamic level Exposure mode Select exposure mode auto and manual You can set manual exposure mode as 1 50 1 10000 You may also customize Gain mode Auto gain if you set it to 20 auto gain will be 20 Fixed gain if you set it to 20 gain will be 20 S...

Страница 41: ...ettings By verifying watermark character you may check if record is edited Check front box to enable function Default watermark character is DigitalCCTV Only number letter and underline are supported max 85 characters Sub Stream Enable Check to enable sub stream Encode mode It supports H 264B H 264M H 264H H 265 MJPEG Resolution Only support 720P and D1 Note Sub stream cannot be over main stream F...

Страница 42: ...f motion detect privacy masking and relay activation Note This device does not support this function Pic size Be consistent with main stream resolution Note This device does not support this function Quality Select snap quality from 6 levels Picture coding size Set the image encoding size there are 8 levels optional or select Custom set the range of 50 1024 Note Pleas select either picture coding ...

Страница 43: ...the same time Please refer to the following sheet for log parameter information Parameter Function Image quality You may drag left mouse to set interest area Select snap quality from 6 levels 4 3 Network 4 3 1 TCP IP The TCP IP interface is shown as in Figure 3 22 Note Some models support dual Ethernet ports so do not set the two ports in the same segment ...

Страница 44: ... you cannot set IP subnet mask gateway Plus IP subnet mask gateway display values from DHCP In static mode you shall manually set IP subnet mask gateway To switch from DHCP to static you must set IP parameters again MAC address Display host MAC address IP version Select IP version IPV4 or IPV6 These two IP addresses both can be accessed IP address Input new IP address to edit and set subnet mask a...

Страница 45: ... a username and password verification turn off the feature you do not need validation See Figure 4 24 Figure 4 24 4 3 3 IP Filter By setting the trusted and banned lists you can enable or disable some users log in to the device Devices allow trusted list the IP address of the user to log in and ban the IP address blacklist users log device Supports adding IP or IP range See Figure 4 25 For example...

Страница 46: ...d List tab Step 5 System informs you it has been successfully saved In Trusted list tab you can Click to modify existing IP address or IP segment Click to delete existing IP address or IP segment Click to clear all IP address in list Note Banned list can be set in similar way as trusted list 4 4 Event 4 4 1 Alarm ...

Страница 47: ...larm output signal Step 3 Click Refresh to search alarm output status Note ITC237 PU1B IR ITC237 PU1B L have a total of 2 channels of alarm output ITC237 PW1B IRZ only has 1 channel of alarm output 4 4 2 Abnormity Note ITC237 PU1B IR ITC237 PU1B L have a total of 2 channels of alarm output ITC237 PW1B IRZ does not have channel of alarm output Figure 4 29 No Storage Card ...

Страница 48: ...42 Figure 4 30 SC Space Lack Figure 4 31 SC Error Figure 4 32 Disconnection ...

Страница 49: ...k box to enable this function Relay out When alarm occurs set corresponding relay out You must enable this function first Relay out delay Alarm will continue for X seconds after motion detect ends You can set X within 10 s 300 s 4 5 Storage 4 5 1 Point Set snapshot storage position Figure 4 34 Point 4 5 2 Local ...

Страница 50: ...44 Figure 4 35 Local 4 5 3 FTP Note When you select FTP as storage method FTP is enabled Set picture name and path click Help to view naming rule ...

Страница 51: ...ble Enable the FTP server storage point Server IP The IP address of the FTP server Encode Mode Picture naming for the Chinese character encoding there are two optional UTF 8 and GB2312 When you click Test two files that use UTF 8 and GB2312 encoding respectively are created on the FTP server to determine how the server is encoded Port FTP server port Username and Password FTP server username and p...

Страница 52: ...46 Figure 4 37 Client It supports upload by IP address or MAC address Max support two clients 4 5 5 Path Figure 4 38 Path ...

Страница 53: ...formation Parameter Function Device name Set device name Language Select language and then close IE When you log in again system language will change Video standard Display device video standard such as PAL Machine Group Input device group Machine Address Input snapshot address of the device 4 6 1 2 Date Time The date time interface is shown as in Figure 4 40 Date Time ...

Страница 54: ...ime format Current time Set current system time Setup becomes effective immediately Sync PC Sync system time with PC time Click on save to refresh system time DST enable Set DST may by date or week Setup becomes effective immediately Synchronize With NTP Check to sync with NTP NTP server Set NTP server address Port Set NTP port no Time zone Set device time zone ...

Страница 55: ...You may switch to other account by clicking on logout Add user Add user within group and set user right By default there are three users admin 888888 and 666666 Their passwords are the same as corresponding username Admin and 888888 are admin account by default while 666666 is user account which has monitor right only Enter add user interface input username and password and select its group Userna...

Страница 56: ...50 Figure 4 42 Add User Modify user Modify existing user s group password right and note See Figure 4 43 Modify User ...

Страница 57: ...8888 and 666666 accounts Account who has right to modify other account can modify other user account besides its own You cannot delete currently logged in account 4 6 2 2 Group The group interface is shown as in Figure 4 44 Group Here you can add and delete group and modify group password The system supports up to 8 user groups Figure 4 44 Group Add group Add user within group and set group right ...

Страница 58: ...ify you may edit group in prompt box The modify group interface is shown as in Figure 4 46 Modify Group Figure 4 46 Modify Group Note You cannot delete admin and user groups You cannot delete group which contains currently logged in user 4 6 3 Default ...

Страница 59: ...re 4 48 Import Export Figure 4 48 Import Export Please refer to the following sheet for log parameter information Parameter Function Export Export system config to local Import Import local config to system Click Import Export Select file path to import or folder to export Click Open Save and view result on WEB 4 6 5 Auto Maintain The auto maintains interface is shown as in Figure 4 49 Auto Mainta...

Страница 60: ... you shall select firmware file Firmware file ends in bin Please maintain stable power supply connection and do not reboot or shut down camera during this process The upgrade interface is shown as in Figure 4 50 Upgrade Figure 4 50 Upgrade Note If system encounters error during upgrading the device may malfunction Do not power off device disconnect device reboot device or close WEB during upgradin...

Страница 61: ...ft build time All info here subject to actual condition 4 7 2 Log The log interface is shown as in Figure 4 52 Log Note Once number of log reaches 1024 it starts to overwrite the earliest log Figure 4 52 Log Please refer to the following sheet for log parameter information ...

Страница 62: ...ck on search button and then you will see logs searched out Click on stop to stop log search Detailed info Click on log to view its detailed information Clear Clear all system log displayed You cannot clear log by type Backup Create backup of displayed log onto current used PC 4 7 3 Online User The online user interface is shown as in Figure 4 53 Online User Here displays online user and their gro...

Страница 63: ...triggers alarm Disk Error When disk has error it triggers alarm No Disk When there is no disk it triggers alarm Black List When the vehicle is on black list it triggers alarm Operation Listen Alarm Alarm type subscribed on device when device alarms it will notify WEB and WEB notifies user Alarm Tone Play Alarm Tone When alarm occurs it has alarm tone which can be customized in setup Tone Path Cust...

Страница 64: ...58 6 Logout Click on logout to exit WEB interface You will see Figure 6 1 Logout To return web interface you have to log in again Figure 6 1 Logout ...