![Dahua H Series Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/dahua/h-series/h-series_quick-start-manual_500335008.webp)
Quick Start Guide
2
Table 1-2
Alarm I/O port introduction
Port
Port Name
Description
Alarm I/O
ALARM_IN (pin1–pin3)
Receives the switch signal of external alarm source.
Connect all the alarm input devices to the same GND
port.
GND (pin4)
ALARM_NO1 (pin5)
Outputs alarm signal to alarm output device.
When connecting to alarm output device, only the
ALARM_NO port and ALARM_COM port with the same
number can be used together.
ALARM_NO2 (pin7)
ALARM_COM1 (pin6)
ALARM_COM2 (pin8)
Connecting Alarm Input/output
1.2
Alarm input/output is available on select models.
Connect alarm input device to the alarm input end of the I/O port. See Figure 1-2.
Step 1
Device collects different states of alarm input port when the input signal is idling and
grounded.
Device collects logic "1" when input signal is connecting to +3V to
+5V or idling.
Device collects logic "0" when input signal is grounded.
Alarm input
Figure 1-2
Connect alarm output device to the alarm output end of the I/O port. The alarm output is
Step 2
relay switch output, which can only connect to NO alarm devices.
The ALARM_NO port and the ALARM_COM port with the same number constitute a switch
for alarm output. See Figure 1-3. The switch is open normally and closes when there is alarm
output.