Intercom Modular Outdoor Station
DHI-VTO4202F Series
User’s Manual
V1.0.2
Страница 1: ...Intercom Modular Outdoor Station DHI VTO4202F Series User s Manual V1 0 2...
Страница 2: ...rmance or unpredictable results NOTE Provides additional information as the emphasis and supplement to the text Revision History No Version Revision Content Release Time 1 V1 0 0 First Release January...
Страница 3: ...or maintenance inconsistent with the information in this guide All the designs and software are subject to change without prior written notice The product updates may cause some differences between t...
Страница 4: ...ra may contact overhead power lines power circuits or electrical lights Ensure power conforms to SELV Safety Extra Low Voltage and that the limited power source is rated AC 24V as specified in IEC6095...
Страница 5: ...ications with strong vibrations such as in boats and vehicles Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or cause a short circuit that ma...
Страница 6: ...ly the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to the outside edge Change...
Страница 7: ...cters such as 111 aaa etc Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can b...
Страница 8: ...e WPA2 PSK encryption mode and use strong passwords Multicast Multicast is used to share video streams between two recorders Currently there are no known issues involving Multicast Deactivate this fea...
Страница 9: ...ecure Auditing Check online users regularly to ensure unauthorized accounts are not logged in to a device Check the equipment log to access the IP addresses used to login to devices and their key oper...
Страница 10: ...in and Reset the Password 12 Login 12 Resetting the Password 13 5 Main Interface 14 6 Local Settings 15 Basic 15 Video and Audio 16 Access Control Settings 18 6 3 1 Local 18 6 3 2 RS 485 19 6 3 3 Pass...
Страница 11: ...X 8 Network 35 Basic 35 8 1 1 TCP IP 35 8 1 2 Port 36 8 1 3 P2P 36 UPnP 36 8 2 1 Enabling UPnP Services 37 8 2 2 Adding UPnP Services 37 SIP Server 38 Firewall 39 9 Log Management 40...
Страница 12: ...s capability card reader fingerprint reader and keypad call buttons information text display and status light indicators The system also offers optional accessories to flush or surface mount a two or...
Страница 13: ...2 2 Intercom Modules Camera Module Front Panel Ref Name Description 1 MIC Inputs audio 2 Camera Monitors door area 3 Speaker Outputs audio Rear Panel...
Страница 14: ...ntrol lock solenoid lock and exit button 3 Ethernet Port Connects unit to Ethernet network 4 Cascade Connection Connection to another Intercom module Ports Ref Name Ref Name 1 GND 8 EOC1 2wires GND fo...
Страница 15: ...4 Status Light Panel Front Panel Ref Description 1 Call indicator 2 Talk indicator 3 Unlock indicator Rear Panel Ref Description 1 Cascade input 2 Cascade output...
Страница 16: ...me Description 1 User directory Add a physical name cards to the slots 2 Call buttons Call a VTH Monitor or the management center Requires programming in the VTO interface Rear Panel Ref Description 1...
Страница 17: ...6 Keypad Module Ref Description 1 Selection 2 Numbers 3 Place call 4 Call management center Rear Panel Ref Description 1 Cascade input 2 Cascade output...
Страница 18: ...7 IC Card Reader Rear Panel Ref Description 1 Cascade input 2 Cascade output...
Страница 19: ...8 Fingerprint Reader Rear Panel Ref Description 1 Cascade input 2 Cascade output...
Страница 20: ...9 Information Text Display Rear Panel Ref Description 1 Cascade input 2 Cascade output Blank Module This module is used to cover extra space if no other functional modules are needed...
Страница 21: ...e required for all modules The Outdoor Video Intercom Panel the left most panel above is the only required module and is the starting point for the cascade connections Note The VTO connection must be...
Страница 22: ...the VTO Enter the default IP address 192 168 1 108 of the VTO in the browser address bar Make sure that the IP address of your PC is in the same network segment as the VTO Device initialization Enter...
Страница 23: ...the VTO Go to the IP address of the VTO in the browser For first time login enter the default IP If you have multiple VTOs we recommend changing the default IP address Network Basic to avoid conflict...
Страница 24: ...ode is sent to the email address configured during initialization Enter the security code in the input box and then click Next If you did not set an email address during initialization contact your su...
Страница 25: ...ings If you restore the VTO to factory settings the unit deletes all data except the external storage You can format the SD card to delete the data in it 2 VTO information View the VTO and system info...
Страница 26: ...in which the management center can be called No Used to differentiate eachVTO Recommend setting the number according to unit or building number and then adding VTOs to the SIP server by using their nu...
Страница 27: ...o message will be saved to the SD cards of both the VTH an the VTO If an SD card is installed in either the VTH or the VTO the video message will be saved in either the SD card of the VTH or the VTO w...
Страница 28: ...ove the overall image Video Standard Select PAL or NTSC according to your area PAL is used in China and Europe and NTSC primarily in the United States and Japan Image Brightness The larger the value t...
Страница 29: ...the door is unlocked longer than the Door Sensor Check Duration the door triggers an alarm and sends an alert to the management center Disable to lock the door after the Unlock Period Install a door c...
Страница 30: ...e parameters of the lock connected through the RS 485 port See Table 6 3 for parameter description Lock connected through the RS 485 port 6 3 3 Password Management Add a username and password used to...
Страница 31: ...to your area Configure DST type start time and end time DST Type Select Date or Week as needed and then configure the specific period Start Time Configure the start time and end time of DST End Time N...
Страница 32: ...Sends information to the DMSS Mobile Application It is recommended to disable this function or the VTO might be exposed to security risks and data leakage Password Reset If turned off you will not be...
Страница 33: ...llows other devices to find this VTO It is recommended to disable this function or the VTO might be exposed to security risks and data leakage Authentication Mode Security Mode recommended Supports lo...
Страница 34: ...er Enter the information and click Save ONVIF devices monitor the VTO by using the account See the user s manual of the ONVIF device for details Upload File Upload audio files to change the sound when...
Страница 35: ...you are using other servers as the SIP server see the corresponding manual for details To configure SIP server parameters see SIP Server for details VTO No Management Adding the VTO to the SIP server...
Страница 36: ...modify or delete a VTO or Clear to delete all added VTOs but the one that you have logged in to cannot be modified or deleted VTH Management 7 2 1 Adding Room Number Add the planned room number tothe...
Страница 37: ...the web interface of the SIP server and then select Local Settings Basic Device properties 1 Set Device Type to Villa Station and then click Save Select Household Setting VTH Management Room number m...
Страница 38: ...ork Registration Type Select public Registration Password Default Click Save Click or to modify or delete a room number Click Clear to delete all room numbers Using the VTO in an Apartment Log in to t...
Страница 39: ...ck Save Adding multiple room numbers Add room numbers in batches 1 Configure the information Unit Layer Amount The number of floors in the apartment Room Amount in One Layer The number of rooms on one...
Страница 40: ...d and then click Issue Card Countdown notice Swipe the card on the VTO You must swipe the card before the countdown time reaches zero Issue card Enter the username click Save and then click Confirm Se...
Страница 41: ...print Enter a username assign unlock permission as needed and then click Save Press the finger onto the scanner VTS Management Add a VTS to the SIP server to use it as the management center The VTS ca...
Страница 42: ...ault IP Address VTS IP address Click Save IP Camera Setting Add an IP camera and an NVR to the VTO working as the SIP server Once added all connected VTH monitors can monitor the video Interfaces migh...
Страница 43: ...device Password Port Keep the default Protocol Select Local or Onvif Stream Type Main Better video quality but requires more bandwidth Extra1 Smoother video with poorer quality but requires less bandw...
Страница 44: ...en select Household Setting Status Status Publish Information Allows you to send messages from the SIP server to the VTH devices connected to it and allows you to view the message history 7 6 1 Send I...
Страница 45: ...k Enter the message title in the Title Field Enter the content of the message in the Contents field Click Confirm 7 6 2 History Info View the information contained in previously sent messages Log in t...
Страница 46: ...CP IP Modify the IP address subnet mask default gateway and DNS of the VTO Select Network Basic TCP IP and port Configure the parameters and click Save The VTO restarts after making any changes You mu...
Страница 47: ...logged in to the VTO download the root certificate and double click to install it Now you can use the HTTPS function mentioned above If you delete the certificate it cannot be undone 8 1 3 P2P Enable...
Страница 48: ...description Parameter Description Service Name Enter the information as needed Service Type Protocol Select TCP or UDP as needed Internal Port Use port number from 1024 through 5000 Do not use port n...
Страница 49: ...figuration Parameter Description IP Addr VTO IP address Port 5060 by default when the VTO that you are logged into is acting as the SIP server Note that this needs to be set to the same port that was...
Страница 50: ...next to Enable Configure the parameters Table 8 4 Firewall type description Type Description Network Access Select either Allowlist or Blocklist and then add an IP address or segment which is allowed...
Страница 51: ...agement Select Search Log to view call history system logs and alarm records unlock records and export them to your PC as needed If storage is full the oldest records are overwritten Back up the recor...
Страница 52: ...vine CA 92618 http us dahuasecurity com Main Line 949 679 7777 Support 877 606 1590 Sales sales usa dahuatech com Support support usa dahuatech com 2021 Dahua Technology USA All rights reserved Design...