Important Safeguards and Warnings 

This chapter describes the contents covering proper handling of the device, hazard prevention, 
and prevention of property damage. Read these contents carefully before using the device, 
comply with them when using, and keep it for future reference. 

Installation and Maintenance Professionals Requirements 

 

All installation and maintenance professionals must have adequate qualifications or 
experiences to install and maintain CCTV systems and electric apparatus. The 
professionals must have the following knowledge and operation skills: 

 

Basic knowledge and installation of CCTV systems. 

 

Basic knowledge and operation skills of low voltage wiring and low voltage electronic 
circuit wire connection. 

 

Basic knowledge and operation skills of electric apparatus installation and maintenance in 
hazardous sites. 

Power Requirements 

 

Install the unit in accordance with the manufacturer’s instructions and in accordance with 
applicable local codes.   

 

All installation and operation must conform to your local electrical safety codes.   

 

Do not overload outlets and extension cords, which may cause fire or electrical shock. 

 

Do not place the camera near or in a place where the camera may contact overhead 
power lines, power circuits, or electrical lights. 

 

Ensure power conforms to SELV (Safety Extra Low Voltage) and that the limited power 
source is rated AC 24V as specified in IEC60950-1. (Power supply requirement is subject 
to the device label). 

 

All input/output ports are SELV circuits. Ensure that SELV circuits are connected only to 
other SELV circuits.   

 

Ground the unit using the ground connection of the power supply to protect the unit from 
damage, especially in damp environments. 

 

Please install easy-to-use device for power off before installing wiring, which is for 
emergent power off when necessary. 

 

Protect the plug and power cord from foot traffic, being pinched, and its exit from the unit. 

 

Do not attempt to service the unit. Opening or removing covers may expose you to 
dangerous voltage or other hazards. Refer all servicing to qualified personnel. 

 

If the unit is damaged and requires service, unplug the unit from the main AC power 
supply and from the PoE supply and refer to qualified service personnel. Damage may 
include, but is not limited to: 

 

The power supply cord or plug is damaged. 

 

Liquid has spilled in or on the unit. 

 

An object has fallen on the unit. 

 

The unit has been dropped and the housing is damaged. 

 

The unit displays a marked change in performance. 

 

The unit does not operate in the expected manner when the user correctly follows the 
proper operating procedures. 

Содержание DHI-VTO2202F-P-S2

Страница 1: ...Intercom Two wire and IP Outdoor Station DHI VTO2202F P S2 User s Manual V1 0 3...

Страница 2: ...rmance or unpredictable results NOTE Provides additional information as the emphasis and supplement to the text Revision History No Version Revision Content Release Time 1 V1 0 0 First Release January...

Страница 3: ...or maintenance inconsistent with the information in this guide All the designs and software are subject to change without prior written notice The product updates may cause some differences between t...

Страница 4: ...ra may contact overhead power lines power circuits or electrical lights Ensure power conforms to SELV Safety Extra Low Voltage and that the limited power source is rated AC 24V as specified in IEC6095...

Страница 5: ...ications with strong vibrations such as in boats and vehicles Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or cause a short circuit that ma...

Страница 6: ...ly the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to the outside edge Change...

Страница 7: ...cters such as 111 aaa etc Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can b...

Страница 8: ...e WPA2 PSK encryption mode and use strong passwords Multicast Multicast is used to share video streams between two recorders Currently there are no known issues involving Multicast Deactivate this fea...

Страница 9: ...ecure Auditing Check online users regularly to ensure unauthorized accounts are not logged in to a device Check the equipment log to access the IP addresses used to login to devices and their key oper...

Страница 10: ...cal 10 6 3 2 RS 485 11 6 3 3 Password Management 12 System 12 Security 14 Wiegand 15 ONVIF User 16 Upload File 17 7 Household Setting 18 VTO No Management 18 VTH Management 19 7 2 1 Adding Room Number...

Страница 11: ...X Firewall 31 9 Log Management 32...

Страница 12: ...intuitive mobile app and an interior color monitor Each IP outdoor station includes a 2 MP wide angle camera with manual rear pivot two way talk and enables remote functions such as snapshot when ring...

Страница 13: ...rcom Modules Camera Module Front Panel No Name Description 1 Microphone 2 Camera 3 Indicator On Door unlocked 4 On In a call 5 On Calling 6 Speaker 7 Call button Call a VTH or the management center 8...

Страница 14: ...nication ALARM_NO Switch quantity output ALARM_COM Switch quantity output VTO2202F 2 wire 48V VTO2201F 24V VTO2202F 2 wire GND VTO2201F GND 3 From left to right DOOR_BUTTON Unlock button DOOR_FB Door...

Страница 15: ...the VTO Enter the default IP address 192 168 1 108 of the VTO in the browser address bar Make sure that the IP address of your PC is in the same network segment as the VTO Device initialization Enter...

Страница 16: ...in the browser For first time login enter the default IP If you have multiple VTOs we recommend changing the default IP address Network Basic to avoid conflict Enter admin as username and the password...

Страница 17: ...uring initialization Enter the security code in the input box and then click Next If you did not set an email address during initialization contact your supplier or customer service for help The secur...

Страница 18: ...to the main interface Log out restart the VTO or restore the VTO to factory settings If you restore the VTO to factory settings the unit deletes all data except the external storage You can format th...

Страница 19: ...ices are monitoring this VTO Calling Center Period Time period in which the management center can be called No Used to differentiate eachVTO Recommend setting the number according to unit or building...

Страница 20: ...needed according to the lighting condition Auto is selected by default Day Night Mode Change the image to color or black white manually or automatically BackLight Mode Disabled No back light Backlight...

Страница 21: ...ain Adjustment Amplifies the video signal to increase image brightness If the value is too large there will be more noise in the image Mirror Displays the image with left and right side reversed Flip...

Страница 22: ...meter First Second Unlock Command Connect a third party phone such as a SIP phone to the VTO and use the command to open the door remotely Door Contact Type NC Normally closed NO Normally open Door Se...

Страница 23: ...lect Local Settings Access Control Settings Password Management Add remove and modify user accounts for unlocking the door Password management System Configure time parameters NTP server and more Sele...

Страница 24: ...ed and then configure the specific period Start Time Configure the start time and end time of DST End Time NTP Enable Enable NTP and enter the IP address of the NTP server The VTO syncronizes time wit...

Страница 25: ...age Mobile Push Notification Sends information to the DMSS mobile application It is recommended to disable this function or the VTO might be exposed to security risks and data leakage Password Reset I...

Страница 26: ...VTO might be exposed to security risks and data leakage Multicast Broadcast Search Allows other devices to find this VTO It is recommended to disable this function or the VTO might be exposed to secu...

Страница 27: ...ugh the ONVIF protocol If you delete an account it cannot be undone Select Local Settings Onvif User Click Add Add an ONVIF user Enter the information and click Save ONVIF devices monitor the VTO by u...

Страница 28: ...ad audio files to change the sound when calling unlocking the door and more Select Local Settings Upload File Select an audio type and click Browse to select the audio file as needed Change the sound...

Страница 29: ...using other servers as the SIP server see the corresponding manual for details To configure SIP server parameters see SIP Server for details VTO No Management Adding the VTO to the SIP server allows t...

Страница 30: ...t the one that you have logged in to cannot be modified or deleted VTH Management 7 2 1 Adding Room Number Add the planned room number tothe SIP server and then configure the room number onVTH devices...

Страница 31: ...information to differentiate each room Last Name Nick Name Room No Enter a room number and then configure the number on a VTH to connect it to the network Registration Type Select public Registration...

Страница 32: ...Swipe the card on the VTO Issue card Enter the username click Save and then click Confirm Send Card Issued access card Other Operations Click to set this card as the main card Once set the icon will...

Страница 33: ...print Enter a username assign unlock permission as needed and then click Save Press the finger onto the scanner VTS Management Add a VTS to the SIP server to use it as the management center The VTS ca...

Страница 34: ...on Password Keep the default setting IP Address VTS IP address Click Save IP Camera Setting Add an IP camera and an NVR to the VTO working as the SIP server Once added all connected VTH monitors can m...

Страница 35: ...word Port Keep the default Protocol Select Local or Onvif Stream Type Main Better video quality but requires more bandwidth Extra1 Smoother video with poorer quality but requires less bandwidth Channe...

Страница 36: ...VTH devices connected to it and allows you to view the message history 7 6 1 Send Info Log in to the web interface of the SIP server and then select Household Setting Publish Information Send Info Sen...

Страница 37: ...nto the Contents field Click Confirm 7 6 2 History Info View the information contained in previously sent messages Log in to the web interface of the SIP server select Household Setting Publish Inform...

Страница 38: ...IP Modify the IP address subnet mask default gateway and DNS of the VTO Select Network Basic TCP IP and port Configure the parameters and click Save The VTO will restart after making any changes You...

Страница 39: ...gged in to the VTO download the root certificate and double click to install it Now you can use the HTTPS function mentioned above If you delete the certificate it cannot be undone 8 1 3 P2P When the...

Страница 40: ...iption Parameter Description Service Name Enter the information as needed Service Type Protocol Select TCP or UDP as needed Internal Port Use port number from 1024 through 5000 Do not use port number...

Страница 41: ...on will fail If anotherVTO is setup as the SIP server Uncheck SIPserver Set ServerType toVTO configure the parameters and thenclick Save Table 8 1 SIP server configuration Parameter Description IP Add...

Страница 42: ...he box next to Enable Configure the parameters Firewall type description Type Description Network Access Select either Allowlist or Blocklist and then add an IP address or segment which is allowed or...

Страница 43: ...ement Select Search Log to view call history system logs and alarm records unlock records and export them to your PC as needed If storage is full the oldest records will be overwritten Back up the rec...

Страница 44: ...vine CA 92618 http us dahuasecurity com Main Line 949 679 7777 Support 877 606 1590 Sales sales usa dahuatech com Support support usa dahuatech com 2021 Dahua Technology USA All rights reserved Design...