background image

Figure 2-1 Modify IP

Step 3 

     Click  Search  setting.

The 

Setting

 interface is displayed.

Step 4 

  Enter the start IP address and end IP address of the network segment in which you want to 

search devices, and then click 

OK

.

All the devices found in the network segment are listed.

Step 5 

  Select one or several devices whose 

Status

 is 

Uninitialized

, and then click 

Initialize

.

The 

Device initialization

 interface is displayed.

Step 6 

 Select the devices that need initialization, and then click 

Initialize

.

The password setting interface is displayed. See Figure 2-2.

Figure 2-2 Password setting

Step 7 

  Set and confirm the password of the devices, then enter a valid email address, and then 

click 

Next

.

The final setting interface is displayed.

Password can be modified or reset in 

System Settings

.

Step 8 

  Select the options according to your needs, and then click 

OK

.

The 

Initialization

 interface is displayed after initialization is completed. Click the success 

icon (

) or the failure icon (

) for the details.

Step 9 

   Click 

Finish

.

The device status in the 

Modify IP

 interface (Figure 2-1) turns to 

Initialized

.

2.2 Modifying Device IP Address

● 

 You can modify IP address of one or multiple devices in one time. This section is based on 

modifying IP addresses in batch.

● 

 Modifying IP addresses in batch is available only when the corresponding devices have the same 

login password.

Step 1 

  Do "Step 1" to "Step 4" in "2.1 Initializing Device" to search devices in your network 

segment.

After clicking 

Search setting

, enter the username and password, and please make sure 

they are the same as what you set during initialization, otherwise there will be "wrong 

password" notice.

Step 2 

  Select the devices which IP addresses need to be modified, and then click 

Modify IP

.

The 

Modify IP Address

 interface is displayed. See Figure 2-3.

Figure 2-3 Modify IP Address

Step 3 

   Select 

Static

 mode, and then enter start IP, subnet mask, and gateway.

● 

 IP addresses of multiple devices will be set to the same if you select the 

Same IP 

checkbox

.

● 

 If DHCP server is available in the network, devices will automatically obtain IP addresses 

from DHCP server when you select 

DHCP

.

Step 4 

 Click 

OK

.

2.3 Logging in to Web Interface

Step 1 

  Open IE browser, then enter the IP address of the device in the address bar, and then press 

Enter.

If the setup wizard is displayed, finish the settings as instructed.

Figure 2-4 Main interface

2.4 Setting Smoke Alarm

Step 1 

  Log in to the web interface and then select 

Setting 

>

 Event 

Smoke Detector Alarm

.

Step 2 

  Setting smoke alarm.

Figure 2-5 Smoke alarm

Step 3 

 Click 

Save

.

3.1Packing List

Check the package according to the following checklist. If you find device damage or any loss, 

contact the after-sales service. 

Table 3-1 Checklist

Name

Quantity

Device

1

Positioning Map

1

Screw Package

1

QSG

1

3.2 Installation Principle

● 

 Multiple devices are needed if the length is greater than 10 meters (32.81 ft).

● 

Make sure the wall is thick enough to install expansion bolts.

● 

 The corresponding signal strength of the device must be above the medium.

● 

Avoid the installation in following areas:

◊ 

High-humidity areas such as kitchens, water heaters, and bathrooms.

◊ 

Areas that are dusty, dirty, or insects frequent.

◊ 

 Areas where the wind speed is too fast such as air conditioner, fan, and heater outlet.

◊ 

Stoves and other hot and easily polluted places.

◊ 

Area blocked by other objects.

◊ 

Within 300 mm (11.81’’) from the lamp.

◊ 

 In closed spaces such as the upper part of the spire room and the corner of the room.

Figure 3-1 Installation position

3.4 Installation Steps

Follow below steps to install the device properly.

Step 1 

 Choose suitable place to install positioning map.

Figure 3-2 Installation (1)

Step 2 

  Drill holes (Φ6 mm [0.24"]) on the wall as the positioning map shows, and then align the 

screw holes on the wall with the expansion bolts. 

Figure 3-3 Installation (2)

Step 3 

 Fix the mounting plate with self-tapping screws.

Step 4 

  Install the battery. 

1)Correctly insert the battery lead terminals.

2)Place the battery in the battery compartment, and arrange the wiring harness.

Step 5 

 Rotate to install the device. Ensure that it is firm and not loose.

Figure 3-4 Installation (3)

Step 6 

 Complete the installation.

Device Installation

3

Figure 3-5 Installation (4)

3.5 Installing SD Card 

● 

SD card slot is available on select models.

● 

 Please disconnect the power from the device before installing the SD card.

● 

Press the reset button for 10 seconds to reset the device.

Figure 3-6 SD Card

4.1 Test

After the installation of the Device or regular maintenance, a test must be carried out to confirm that 

the Device is operating properly.

During the testing process, the defective Device should be addressed according to "FAQ" and 

"Maintenance", and then tested again. If it fails to complete the test successfully, please send the 

Device to the manufacturer for repair.

Do not use real flame for testing in case of detector malfunction or fire.

Test and Operation

4

Step 2 

  Enter the user name and password in the login box, and then click 

Login

.

Step 3 

  For first time login, click 

Click Here to Download Plugin

, and then install the plugin as 

instructed.

The main interface is displayed when the installation is finished. See Figure 2-4.

4.2 Status and Operation

Device self-test

After installing battery, the indicator flashes periodically. Press 

Test

 button, buzzer beeps and red 

indicator flashes quickly.

Alarm

When the smoke in the detector reaches a predetermined concentration value or intelligent event is 

triggered, the indicator light flashes quickly in conjunction with the alarm sound. Press the 

Silence 

button, the device will temporarily stop emitting the alarm sound. When the smoke concentration 

decreases to a safe and low level, the device returns to its normal working state.

Sensor fault

When the sensor fails to work, the red indicator light flashes every minute.

Low voltage

When the battery voltage is lower than the certain level, the red indicator light flashes with a short 

beep every minute. Please replace the battery in time.

5.1 Green Power indicator light does not flash

Solutions:

● 

 Check the connection of power cable.

● 

Contact with manufacturer.

5.2 Press Test button, there is no alarm

Solutions:

Disassemble the device to check whether the battery is properly installed.

5.3 Alarm sounds continuously

Solutions:

The battery is low voltage. Please replace the battery.

5.4 Cannot log in to the web interface

Solutions:

● 

Enter the correct user name and password.

● 

 Check whether the network cable is in good condition, and whether the network configuration is 

correct; pull out the network cable and plug in again. 

● 

 Use the standard power adapter. See the camera label for the power adapter selection.

● 

 Clear the buffer of the browser, check whether the browser permission is enabled, or change the 

browser.

FAQ

5

To keep your device in good working condition, please follow these requirements.

● 

 Simulate fire alarm test: once half a year (recommended). 

 Under normal working conditions, press the Test button to ensure that the Device can work 

normally. If there is a malfunction, please repair it in time. After cleaning, please install the Device 

and test again.

● 

 Clean the shell: at least once per year (recommended). 

 Keep the Device free of dust or inserts by gently vacuuming the shell with a soft brush attachment 

when required. Avoid cleaning solutions on the Device to prevent the possibility of contaminating 

the sensor.

Maintenance

6

3.3 Installation Position

Содержание DHI-HY-SAV849HAP-E

Страница 1: ...AI Fire Smoke Sensing Network Camera Quick Start Guide V1 0 0 1 2 51 32 19297 000...

Страница 2: ...e operations that do not comply with the manual The manual would be updated according to the latest laws and regulations of related jurisdictions For detailed information refer to the paper manual CD...

Страница 3: ...ion scenario conforms to installation requirements Contact your local retailer or customer service center if there is any problem All installation and operations shall conform to your local electrical...

Страница 4: ...85 port Controls external devices For more information about I O port see Table 1 3 Port Port Name Description Alarm I O ALARM_OUT1 Outputs alarm signal to alarm device When connecting to alarm device...

Страница 5: ...A If the voltage is higher than 12V please use an additional electric relay Figure 1 4 Alarm output Step 3 Log in web interface and configure alarm input and alarm output in alarm setting The alarm in...

Страница 6: ...rns to Initialized 2 2 Modifying Device IP Address You can modify IP address of one or multiple devices in one time This section is based on modifying IP addresses in batch Modifying IP addresses in b...

Страница 7: ...gth of the device must be above the medium Avoid the installation in following areas High humidity areas such as kitchens water heaters and bathrooms Areas that are dusty dirty or insects frequent Are...

Страница 8: ...ith self tapping screws Step 4 Install the battery 1 Correctly insert the battery lead terminals 2 Place the battery in the battery compartment and arrange the wiring harness Step 5 Rotate to install...

Страница 9: ...ry minute Please replace the battery in time 5 1 Green Power indicator light does not flash Solutions Check the connection of power cable Contact with manufacturer 5 2 Press Test button there is no al...

Отзывы: