AI-Fire Smoke Sensing
Network Camera
Quick Start Guide
General
This manual introduces the functions and operations of the 5 MP IR AI-fire Smoke Sensing Network
Camera (hereinafter referred to as "the Device").
Models
DHI-HY-SAV849HAP-E, DHI-HY-SAV849HAN-E
Safety Instructions
The following categorized signal words with defined meaning might appear in the manual.
Foreword
Signal Words
Meaning
DANGER
Indicates a high potential hazard which, if not avoided, will result in death
or serious injury.
WARNING
Indicates a medium or low potential hazard which, if not avoided, could
result in slight or moderate injury.
CAUTION
Indicates a potential risk which, if not avoided, could result in property
damage, data loss, lower performance, or unpredictable result.
TIPS
Provides methods to help you solve a problem or save you time.
NOTE
Provides additional information as the emphasis and supplement to the
text.
About the Manual
●
The manual is for reference only. If there is inconsistency between the manual and the actual
product, the actual product shall prevail.
●
We are not liable for any loss caused by the operations that do not comply with the manual.
●
The manual would be updated according to the latest laws and regulations of related jurisdictions.
For detailed information, refer to the paper manual, CD-ROM, QR code or our official website. If
there is inconsistency between paper manual and the electronic version, the electronic version
shall prevail.
●
All the designs and software are subject to change without prior written notice. The product
updates might cause some differences between the actual product and the manual. Please
contact the customer service for the latest program and supplementary documentation.
●
There still might be deviation in technical data, functions and operations description, or errors in
print. If there is any doubt or dispute, we reserve the right of final explanation.
●
Upgrade the reader software or try other mainstream reader software if the manual (in PDF
format) cannot be opened.
●
All trademarks, registered trademarks and the company names in the manual are the properties of
their respective owners.
●
Please visit our website, contact the supplier or customer service if there is any problem occurring
when using the device.
●
If there is any uncertainty or controversy, we reserve the right of final explanation.
The manual will help you to use the Device properly. Read the manual carefully before using the
Device, and keep it well for future reference.
Operation Requirements
WARNING
Never ignore any alarm. Failure to respond may lead to serious injury or death.
●
Make sure that the power supply of the device works properly before use.
●
Use the device according to the operating environment.
●
Only use the device within the rated power range.
●
Transport, use and store the device under allowed humidity and temperature conditions.
●
Prevent liquids from splashing or dripping on the device. Make sure that there are no objects filled
with liquid on top of the device to avoid liquids flowing into it.
Installation Requirements
WARNING
●
Strictly abide by local electrical safety standards, and make sure that the voltage in the area is
steady and conforms to the power requirements of the device.
●
Failure to properly install and operate this device will prevent proper operation of the Device and
will prevent its response to fire hazards.
●
All installation and operations shall conform to your local electrical safety regulations, fire
protection regulations, and other relevant regulations.
●
Make sure that the application scenario conforms to installation requirements. Contact your local
retailer or customer service center if there is any problem.
●
Use the Device according to the operating environment.
●
Keep the original packing material well because you might need it to pack the Device and
●
send it back for repair.
●
Observe all safety procedures and wear required protective equipment provided for your use while
working at heights.
●
Do not expose the device to direct sunlight or heat sources.
●
Keep the original packing material well because you might need it to pack the device and send it
back for repair.
●
Make sure the application scenario conforms to installation requirements. Contact your local
retailer or customer service center if there is any problem.
●
All installation and operations shall conform to your local electrical safety requirements, fire
protection regulations, and other relevant regulations.
Maintenance Requirements
●
Do not clean the device with any cleaning products.
●
Do not paint the device. Paint will seal the bents and interfere with the sensor’s ability to work
normally.
Important Safeguards and Warnings
1.1 Introduction
Together with high-performance microprocessor and advanced electronic technology, the 5 MP IR
AI-fire Smoke Sensing Network Camera has the characteristics of high sensitivity and stability.
Based on the mounting bracket, it can be easily installed on the ceiling. With built-in high-decibel
buzzer, it will send out a sound and light alarm signal in time to remind users to take effective
measures immediately when the smoke concentration reaches the alarm setting value. Application
scenarios include chain stores, unattended base stations, unmanned power distribution rooms, ATM
areas, libraries and places where both fire alarm and video surveillance are needed.
1.2 Dimensions
Figure 1-1 Dimensions (mm[inch])
1.3 Technical Information
Table 1-1 Specification
Specification
Introduction
Model
DHI-HY-SAV849HAP-E, DHI-HY-SAV849HAN-E
Communication
1 RJ-45 PoE 10M/100M Ethernet ports
Indicators
●
Standby: Green indicator flashes once per minute
●
Alarm: Red indicator flashes once per second
●
Fault: Red indicator flashes once per minute
●
Self-test: Red indicator flashes once per second
●
Low voltage: Red indicator flashes once per minute
Protection Area of Smoke Sensor 30 m²–60 m²
Operating Principle
Photoelectric
Alarm Method
Sound and LED Indicator
Power Supply
DC12V / PoE and 3V lithium battery
Operating Current
≤30uA (Camera excluded)
≤300mA (Camera included)
Back-up Battery Life
3–5 years
Operating Temperature
–10°C to +55°C (+14°F to +131°F)
Operating Humidity
0%–95% RH (non-condensing)
1.4 Cable
●
Cable type might vary with different devices, and the actual product shall prevail.
●
Please waterproof all the cable joints with insulating tape and waterproof tape to avoid short circuit
and water damage. For the detailed operation, see the FAQ manual.
Figure 1-2 Cable list
Table 1-2 Cable information
No.
Port name
Description
1
Audio input
RCA port. Connects to sound pickups to receive audio signal.
2
Audio output
RCA port. Connects to speaker to output audio signal.
3
Ethernet port
●
Connects to network with network cable.
●
Provides power to the device with PoE.
PoE is available on select models.
4
Alarm I/O
Includes alarm signal input and output ports, and the number of I/O
ports might vary on different devices
5
Power input
Inputs 12 VDC power. Be sure to supply power as instructed in the
manual.
Device damage might occur if power is not supplied correctly.
6
RS 485 port
Controls external devices.
For more information about I/O port, see Table 1-3.
Port
Port Name
Description
Alarm I/O
ALARM_OUT1
Outputs alarm signal to alarm device.
When connecting to alarm device, only the ALARM_
OUT port and ALARM_OUT_GND port with the same
number can be used together.
ALARM_OUT_GND1
ALARM_OUT2
ALARM_OUT_GND2
ALARM_IN1
Receives the switch signal of external alarm source.
Connect different alarm input devices to the same
ALARM_IN_GND port.
ALARM_IN2
ALM_IN_GND
Table 1-3 Alarm information
1.5 Alarm Configuration
The Device can connect to external alarm input/output device through input/output port.
Cut off power before connecting cables.
Step 1
Connect alarm input device to alarm input port of I/O cable.
Device collects different states of alarm input port when the input signal is idling and being
grounded.
●
When input signal is connecting to +3V to +5V or idling, the Device collects logic "1".
●
When input signal is grounded, the Device collects logic "0."
Figure 1-3 Alarm input
Step 2
Connect alarm output device to the alarm output end of the I/O port. The alarm output is
open-drain output, which works in the following modes.
●
Mode A: Level application. Alarm outputs high and low level, and the alarm outlet is OD,
which requires external pull-up resistance (10K Ohm typical) to work. The maximum
external pull-up level is 12V, maximum port current is 300mA and the default output signal
is high level (external pull-up voltage). The default output signal switches to low level
when there is alarm output (As long as the operating current below 300mA, the output low
level voltage is lower than 0.8V).
●
Mode B: Switch application. Alarm output is used to drive external circuit, the maximum
voltage is 12V and the maximum current is 300mA. If the voltage is higher than 12V,
please use an additional electric relay.
Figure 1-4 Alarm output
V1.0.0
Product Information
1
Step 3
Log in web interface, and configure alarm input and alarm output in alarm setting.
●
The alarm input in the web interface is corresponding to the alarm input end of the I/O
port. There will be high level and low level alarm signal generated by the alarm input
device when alarm occurs, set the input mode to "NO" (default) if the alarm input signal is
logic "0" and to "NC" if the alarm input signal is logic "1".
●
The alarm output in the web interface is corresponding to the alarm output end of the
device, which is also alarm output end of the I/O port.
Alarm Classification
Smoke alarm, fault alarm, undervoltage alarm, AI alarm
Alarm Sound Pressure
≥80 dB (A) @ 3 m (9.84 ft)
Image Sensor
1/2.7" CMOS
Focal Length
2.0mm
Max. Pixel
500W
Day/Night
Auto (ICR)
Video Compression
H.265;H.264;H.264H;H.264B
L:W
16:9
Max. Frame Rate
2592(H)×1944(V)
Bit Rate Control
Variable/Constant
Alarm Linkage
Smoke alarm, AI alarm
Reset
Support
Alarm Input
2 channels in: 5mA 3V–5V DC
Alarm Output
2 channels out: 300mA 12V DC
Temperature Measuring Range
–20°C to +120°C (-4°F to +248°F)
Dimensions
φ120 mm × H79mm (4.72" × 3.11" )
Weight (with battery)
420 g (0.93 lb)
Figure 1-5 The alarm interface
Device initialization and IP address setting can be finished with the "ConfigTool" or in web interface.
For more information, see the Web Operation Manual.
●
Device initialization is available on select models, and it is required at first use or after the device
being reset.
●
Device initialization is available only when the IP addresses of the device (192.168.1.108 by
default) and the PC stay in the same network segment.
●
Plan useable network segment properly to connect the device to the network.
●
The following figures and interfaces are for reference only, and the actual product shall prevail.
2.1 Initializing Device
Step 1
Double-click "ConfigTool.exe" to open the tool.
Step 2
Click
.
The
Modify IP
interface is displayed. See Figure 2-1.
Network Configuration
2
1.2.51.32.19297-000