13 

 

Different modes support different unlock methods, and the actual interface shall prevail. 

 

Administrator login 

 

Содержание DHI-ASI7213X-V1-T1

Страница 1: ...User s Manual Face Recognition Access Controller User s Manual V1 0 0...

Страница 2: ...e text Revision History Version Revision Content Release Time V1 0 0 First release September 2020 About the Manual The manual is for reference only If there is inconsistency between the manual and the...

Страница 3: ...he manual in PDF format cannot be opened All trademarks registered trademarks and the company names in the manual are the properties of their respective owners Please visit our website contact the sup...

Страница 4: ...ler under allowed humidity and temperature For the access controller with a temperature monitoring unit Install the temperature monitoring unit in a windless indoor environment and maintain the indoor...

Страница 5: ...Password 14 3 6 4 Administrator Password 15 User Management 15 3 7 1 Adding New Users 15 3 7 2 Viewing User Information 17 Access Management 17 3 8 1 Period Management 17 3 8 2 Unlock 19 3 8 3 Alarm C...

Страница 6: ...er 45 4 5 2 SIP Server 47 4 5 3 Door Station Management 48 4 5 4 Indoor Monitor Management 50 4 5 5 Configuring the Managing Device 52 4 5 6 Online Status 53 4 5 7 Call Logs 54 Data Capacity 55 Video...

Страница 7: ...ment 70 Upgrade 70 Version Information 71 Online User 71 System Log 71 4 17 1 Querying Logs 72 4 17 2 Backup Logs 72 4 17 3 Admin Log 72 Exit 73 5 FAQ 74 Notes of Temperature Monitoring 75 Notes of Fa...

Страница 8: ...an recognize more than 360 positions on human face Face verification accuracy 99 5 low false recognition rate Support profile recognition the profile angle is 0 90 Support liveness detection Support d...

Страница 9: ...2 Networking Dimension and Component Dimensions and components of model X mm inch Table 1 1 Component description 1 No Name No Name 1 Temperature monitoring unit 3 Dual cameras 2 MIC 4 Display...

Страница 10: ...d components of model Y mm inch Table 1 2 Component description 2 No Name No Name 1 Temperature monitoring unit 5 Display 2 IR light 6 Card swiping area 3 Phototransistor 7 White LED illuminator 4 Dua...

Страница 11: ...s and door contacts Cable connections Table 2 1 Component description No Name 1 USB port 2 Power port 3 Ethernet port 4 Ethernet port only supported by 7 inch model B access controllers For detail fun...

Страница 12: ...it button lock control and firefighting linkage will be invalid Purple A RS 485 positive electrode input connected to external card reader output connected to controller or connected to door control s...

Страница 13: ...s away from the access controller the minimum illumination should be no less than 100 Lux It is recommended that the access controller is installed indoors at least 3 meters away from windows and door...

Страница 14: ...ake away the heat from the forehead which will affect the accuracy of temperature monitoring Sweating Sweating is a way for the body to automatically cool down and dissipate heat When the body sweats...

Страница 15: ...tion The installation of model X and model Y is the same This section takes model X as an example Make sure that the distance between the camera and ground is 1 4 meters Installation height Installati...

Страница 16: ...holes in the bracket Fix the bracket on the wall by installing the expansion screws into the six bracket installation holes Connect cables for access controller See 2 1 Cable Connections Hang the acce...

Страница 17: ...con Turn to the first page of the list Turn to the last page of the list Turn to the previous page of the list Turn to the next page of the list Return to the previous menu Enable Disable Initializati...

Страница 18: ...ssword The password must consist of 8 to 32 non blank characters and contain at least two types of characters among upper case lower case number and special character excluding Standby Interface You c...

Страница 19: ...2 Date Time Current date and time 3 Network status and USB status 4 Main menu icon Only the administrator can enter the main menu 5 Password unlock icon 6 Administrator password unlock icon 7 Tap to...

Страница 20: ...13 Different modes support different unlock methods and the actual interface shall prevail Administrator login...

Страница 21: ...words and cards 3 6 1 Cards Put the card at the card swiping area to unlock the door 3 6 2 Face Make sure that your face is centered on the face recognition frame and then you can unlock the door 3 6...

Страница 22: ...plans and anti passback Administrator password cannot be used when NC is selected at 3 8 1 5 NC Period Tap on the homepage Tap Please Enter Administrator PWD Enter the administrator password and then...

Страница 23: ...ure of the new user s face automatically Card You can register five cards at most for each user On the card registration interface enter your card number or swipe your card and then the card informati...

Страница 24: ...eed the maximum times they cannot unlock the door again Patrol Paroling users can get their attendance tracked but they have no unlock permission VIP When VIP unlocks the door service personnel will g...

Страница 25: ...holiday groups into holiday plans You can use holiday plans to manage user access permission in different holiday groups Users can only unlock the door in the period that you set 3 8 1 4 NO Period If...

Страница 26: ...one of all the unlocking methods Select Access Unlock Mode Unlock Mode Element multiple choice Select unlock mode s Tap a selected unlock mode again the unlock mode will be deleted Select a combinati...

Страница 27: ...ds For example in period 1 the door can only be unlocked through cards and in period 2 doors can only be locked through faces Select Access Unlock Mode Unlock by Period Unlock by period Set starting t...

Страница 28: ...ettings Unlock Mode There are three options Card PWD and Face Valid User Valid users are the ones that have unlock permission Doors can be unlocked only when the number of users to unlock the doors eq...

Страница 29: ...n tries to enter again and the person will have no permission to unlock the door any more If a person enters without the identity checked an alarm will be triggered when the person tries to exit with...

Страница 30: ...he door status is normally closed which means the door will not be unlocked Normal If Normal is selected the door will be unlocked and locked depending on your settings 3 8 5 Lock Holding Time Lock Ho...

Страница 31: ...hout requiring DDNS port mapping or transit server Make sure that the computer used to log in to the web is in the same LAN with the device 7 inch model X access controllers of have dual NICs The defa...

Страница 32: ...reading and writing functions are connected to the access controller Serial Input is selected to enable access card information to be sent to the access controller and the management platform For acc...

Страница 33: ...gits Pulse Width You can set pulse width and pulse interval Pulse Interval Output Data Type You can select the types of output data User ID If User ID is selected and then user ID will be output Card...

Страница 34: ...the access controller can recognize faces as needed The value changes according to the face sizes and the distance between faces and the lens The closer the face is to the lens the greater the value...

Страница 35: ...his parameter according to the comparison between the monitored temperature and the actual temperature For example if the monitored temperature is 0 5 C lower than the actual temperature the correctio...

Страница 36: ...ust the volume 3 10 7 IR Light Brightness Adjustment The larger the value is the clearer the images will be otherwise the more unclear the images will be 3 10 8 Restore to Factory Settings Data will b...

Страница 37: ...ormation from one access controller to the USB before using USB to import information to another access controller USB can also be used to update the program 3 11 1 USB Export You can export data from...

Страница 38: ...rive will be imported into the access controller 3 11 3 USB Update USB flash drive can be used to update the system Rename the updating file name to update bin and save the update bin file in the root...

Страница 39: ...rotocol discrepancy Security Module If the security module is enabled you need to purchase access control security module separately The security module needs separate power supply to provide power On...

Страница 40: ...I commands otherwise HTTP will be used When HTTPS is enabled the access controller will restart automatically CGI Common Gateway Interface CGI offers a standard protocol for web servers to execute pro...

Страница 41: ...matically taken This function is ON by default Clear All Captured Photos Tap the icon and you can delete all captured photos Face Privacy Set different levels to blur the standby interface 3 12 2 Resu...

Страница 42: ...35 User Photo Name User photo name Only Name Only name...

Страница 43: ...36 Success or Failure Success or failure Record You can search for all unlocking records Select Record Search Punch Records...

Страница 44: ...Test When you use the access controller for the first time or when the access controller malfunctioned you can use auto test function to check whether the access controller can work normally Do actio...

Страница 45: ...en you select Auto Test the access controller will guide you to do all the auto tests System Info You can view data capacity device version and hardware version of the access controller on the System...

Страница 46: ...orted Otherwise you might not log in to the web Make sure that the computer used to log in to the web is in the same LAN with the device 7 inch model X access controllers of have dual NICs The default...

Страница 47: ...an email address to receive the security code Click Next Auto check You can decide whether to select Auto Check or not It is recommended that Auto Check be selected to get the latest program in time...

Страница 48: ...d for ETH2 is 192 168 2 108 Login Enter the user name and password The default administrator name is admin and the password is the login password after initializing the access controller Modify the ad...

Страница 49: ...rated by scanning the same QR code If security codes become invalid to get more security codes refresh the QR code You need to send the content that you get after you scan the QR code to the designate...

Страница 50: ...non blank characters and contain at least two types of characters among upper case lower case number and special character excluding Click OK and the reset is completed Alarm Linkage 4 4 1 Setting Al...

Страница 51: ...are NO by default if fire link is enabled Alarm Output Enable The relay can output alarm information will be sent to the management platform if the Alarm Output is enabled Duration Sec The alarm durat...

Страница 52: ...log Select a time range and alarm type and then click Query Query results Call Configuration The access controller can work as a door station and call other devices 4 5 1 Configuring the Access Contr...

Страница 53: ...ideo and sound may be lagging with poor network Mode2 Not real time call but ensures smooth video and sound Click Confirm 4 5 1 2 Other Device as SIP Server Log in to the web Select Talkback Setting L...

Страница 54: ...ns to the SIP server so that they can talk to each other The SIP server can be the access controller or other door stations When the access controller works as the SIP server it can connect up to 50 o...

Страница 55: ...rameter description 1 Parameter Description IP Address The IP address of the door station working as the SIP server Port 5060 by default Username Keep the default values Password SIP Domain Must be VD...

Страница 56: ...back Setting VTO No Management Click Add VTO No management Configure the parameters Add a door station Table 4 5 Parameter description Parameter Description Rec No Number of the door station Register...

Страница 57: ...Click OK 4 5 4 Indoor Monitor Management When the access controller works as the SIP server add all relevant indoor monitors to call them When there are master and extension indoor monitors you need t...

Страница 58: ...tension indoor monitors with 1 2 3 For example the master indoor monitor is 101 0 extension monitors are 101 1 101 2 and 101 3 Register Type Keep the default value Register Password Click OK You can a...

Страница 59: ...ccess controller works as the SIP server add other managing devices to call them Log in to the web Select Talkback Setting VTS Management Click Add Add managing devices Enter the information VTS No co...

Страница 60: ...of the managing device change Click and enter the new password or IP address and then click OK Delete a managing device Click 4 5 6 Online Status When the access controller works as the SIP server ad...

Страница 61: ...54 Status 4 5 7 Call Logs You can check up to 1024 call logs Log in to the web Select Talkback Setting Call Optional Click Export Data to export all the logs Call logs...

Страница 62: ...hat the access controller can hold on the Data Capacity interface Data capacity Video Setting You can set parameters including data rate image parameters brightness contrast hue saturation and more an...

Страница 63: ...ich consecutive frames appear on a display The frame rate range is 1 30 fps Bit Rate The number of bits that are conveyed or processed per unit of time There are five options 2 Mbps 4 Mbps 6 Mbps 8 Mb...

Страница 64: ...nd white In this mode images are in black and white Back Light Mode Close Without backlight compensation BLC Backlight compensation corrects regions with extremely high or low levels of light to maint...

Страница 65: ...select Outdoor in the Anti flicker drop down list you can select Shutter Priority as the exposure mode Exposure modes of different devices might vary and the actual product shall prevail Shutter The l...

Страница 66: ...etection area you draw will be a non motion detection area if you draw in the default motion detection area Motion detection area Set sensitivity and threshold Sensitivity represents the ability of ea...

Страница 67: ...g 4 7 6 Image Mode There are three options indoor outdoor and other Select Indoor when the access controller is installed indoors select Outdoor when the access controller is installed outdoors and se...

Страница 68: ...61 Local coding Click OK Face Detect You can configure human face related parameters on this interface to increase the accuracy of the face recognition Select Face Detect...

Страница 69: ...ized Anti fake Threshold This function prevents people from unlocking by human face images or face models There are two options Enable and Close Fill Light Brightness Setting You can set fill light br...

Страница 70: ...hite light camera and 2 is IR light camera Draw Target Click Draw Target and then you can draw the minimum face detection frame Click Remove All and you can remove all the frames you drew Detect Regio...

Страница 71: ...is not detected during face recognition Mask reminder Mask is detected during face recognition If the person is detected without wearing a mask the system will prompt mask reminder and passage is allo...

Страница 72: ...ent Subnet Mask Default Gateway Preferred DNS Server Set IP address of the preferred DNS server Alternate DNS Server Set IP address of the alternate DNS server Click OK to complete the setting 4 9 2 P...

Страница 73: ...port used for auto registeration Sub Device ID Access controller ID assigned by the server Click OK to complete the setting 4 9 4 P2P Peer to peer computing or networking is a distributed application...

Страница 74: ...ety Management 4 10 1 IP Authority Select a cybersecurity mode as needed IP authority 4 10 2 Systems 4 10 2 1 System Service There are four options SSH PWD Reset Enable CGI and HTTPS Refer to 3 12 Fea...

Страница 75: ...hat you have downloaded to install the certificate Install the certificate by following the onscreen instructions User Management You can add and delete users modify users passwords and enter an email...

Страница 76: ...tor and user have different permission of ONVIF server Create onvif users as needed Onvif user Maintenance You can make the access controller reboot itself in idle time to improve the running speed of...

Страница 77: ...r the access controller When more than one access controller needs the same configuration you can configure parameters for them by importing or exporting configuration files Configuration management U...

Страница 78: ...s serial number MCU version web version security baseline version and system version Online User You can view username IP address and user login time on the Online User interface Online user System Lo...

Страница 79: ...ts type click Query and logs meet the conditions will be displayed 4 17 2 Backup Logs Click Backup to back up the logs displayed 4 17 3 Admin Log Enter Admin ID on the Admin Log interface click Query...

Страница 80: ...73 Admin log Hover the mouse cursor over and then you can see detailed information of the current user Exit Click click OK and then you will log out the web interface...

Страница 81: ...the Wiegand port Check whether the GND cable of access controller and the external controller are connected 4 Configurations cannot be made after the administrator and password are forgotten Delete ad...

Страница 82: ...monitoring unit away from sources of thermal interference The factors such as sunlight wind cold air and air conditioning cold and warm air will affect the surface temperature of human body which wil...

Страница 83: ...e device at least two meters away from light source and at least three meters away from windows or doors otherwise backlight and direct sunlight might influence face recognition performance of the dev...

Страница 84: ...e influenced Appendix Figure 2 2 Appropriate face position Requirements of Faces Make sure that the face is clean and forehead is not covered by hair Do not wear glasses hats heavy beards or other fac...

Страница 85: ...he management platform make sure that image resolution is within the range 150 300 600 1200 image pixels are more than 500 500 image size is less than 75 KB and image name and person ID are the same M...

Страница 86: ...unction to obtain timely information of firmware updates released by the manufacturer We suggest that you download and use the latest version of client software Nice to have recommendations to improve...

Страница 87: ...ve we recommend that you use encrypted transmission function to reduce the risk of audio and video data being stolen during transmission Reminder encrypted transmission will cause some loss in transmi...

Страница 88: ...81 Enable IP MAC address filtering function to limit the range of hosts allowed to access the device...