background image

 

III 

Ideally, you want to prevent any unauthorized physical access to your system. The best way to 

achieve  this  is  to  install  the  recorder  in  a  lockbox,  locking  server  rack,  or  in  a  room  that  is 

behind a lock and key. 

 

15. Connect IP Cameras to the PoE Ports on the Back of an NVR:

 

Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world 

and cannot be accessed directly. 

 

16. Isolate NVR and IP Camera Network

 

The  network  your  NVR  and  IP  camera  resides  on  should  not  be  the  same  network  as  your 

public computer network. This will prevent any visitors or unwanted guests from getting access 

to the same network the security system needs in order to function properly. 

Содержание DHI-ACS2204C-H

Страница 1: ...Two door Slave Access Controller User s Manual V1 0 1 ...

Страница 2: ... the credentials to your devices to help ensure that only authorized users are able to access the system 2 Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can be changed to any set of numbers between 1025 65535 Avoiding the default ports reduces the risk of outsiders being able ...

Страница 3: ...or multiple users ensure that each user only has rights to features and functions they need to use to perform their job 10 UPnP UPnP will automatically try to forward ports in your router or modem Normally this would be a good thing However if your system automatically forwards the ports and you leave the credentials defaulted you may end up with unwanted visitors If you manually forwarded the HTT...

Страница 4: ... Ports on the Back of an NVR Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and cannot be accessed directly 16 Isolate NVR and IP Camera Network The network your NVR and IP camera resides on should not be the same network as your public computer network This will prevent any visitors or unwanted guests from getting access to the same network the securi...

Страница 5: ...might collect personal data of others such as face fingerprints car plate number Email address phone number GPS and so on You need to be in compliance with the local privacy protection laws and regulations to protect the legitimate rights and interests of other people by implementing measures include but not limited to providing clear and visible identification to inform data subject the existence...

Страница 6: ...ns description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader software or try other mainstream reader software if the Guide in PDF format cannot be opened All trademarks registered trademarks and the company names in the Manual are the properties of their respective owners Please visit our website contact the supplier or customer servic...

Страница 7: ...ange Please don t dismantle the device arbitrarily Please transport use and store the device within allowed humidity and temperature range Power Requirement Please make sure to use batteries according to requirements otherwise it may result in fire explosion or burning risks of batteries To replace batteries only the same type of batteries can be used The product shall use electric cables power ca...

Страница 8: ... Installation 4 3 4 Disassembly 5 3 5 Wiring Description 6 3 5 1 Wiring Description of CAN Bus 7 3 5 2 Wiring Description of Exit Button Door Sensor 7 3 5 3 Wiring Description of External Alarm Input 8 3 5 4 Wiring Description of External Alarm Output 8 3 5 5 Wiring Description of Lock 9 3 5 6 Wiring Description of Internal Alarm Output 10 3 5 7 Wiring Description of Reader 10 3 6 DIP Switch 11 3 ...

Страница 9: ... groups of control output electric lock 2 and alarm output 3 With RS485 port it may extend to connect lift control module alarm or household control module Support CAN bus and connect master controller FLASH storage capacity is 16M which may extend to 32M max supports 20 000 card holders and 30 000 offline records Support illegal intrusion alarm exit overtime alarm duress card alarm and duress cod...

Страница 10: ...n please check according to Table 2 1 No Name Quantity 1 Access controller 1 2 Installation positioning drawing 1 3 Accessory kit screw expansion pipe and wiring terminal 1 4 Quick start guide 1 5 Certificate of qualification 1 Table 2 1 ...

Страница 11: ...System Structure System structure of two door slave access controller door lock and reader is shown in Figure 3 1 Figure 3 1 3 2 External Dimension Its appearance and dimension is shown in Figure 3 2 and Figure 3 3 The unit is mm ...

Страница 12: ...e are two installation modes Mode 1 fix the whole device onto the wall with screws Mode 2 install U shaped guide rail and hang the whole device onto the wall U shaped guide rail is a self bought fitting Mode 1 Installation diagram is shown in Figure 3 4 ...

Страница 13: ...of the device into upper groove of U shaped guide rail Step 3 Push the snap joint at the bottom of the device upwards The installation is completed when you hear the fitting sound 3 4 Disassembly If the device is installed with mode 2 please disassemble it according to Figure 3 6 Align a screwdriver with the snap joint press it down and the snap joint will pop up so the ...

Страница 14: ...6 whole device can be disassembled smoothly Figure 3 6 3 5 Wiring Description Device wiring diagram is shown in Figure 3 7 Figure 3 7 Interfaces are described in Table 3 1 ...

Страница 15: ...s are described in Table 3 2 No Description 16 Lock status indicator 17 18 Alarm status indicator 19 20 Power indicator Table 3 2 3 5 1 Wiring Description of CAN Bus Wiring terminals of CAN bus are described in Table 3 3 Interface Wiring Terminal Description CAN bus CANL CAN bus input CANH CANL CAN bus output CANH Table 3 3 3 5 2 Wiring Description of Exit Button Door Sensor Corresponding wiring t...

Страница 16: ...ng Terminal Description External alarm input ALM1 Alarm input interface 1 External alarm input interfaces are able to connect smoke detector and IR detector etc ALM2 Alarm input interface 2 ALM3 Alarm input interface 3 ALM4 Alarm input interface 4 ALM5 Alarm input interface 5 reserved GND Shared by alarm input interface 1 2 3 4 and 5 Table 3 5 3 5 4 Wiring Description of External Alarm Output Ther...

Страница 17: ... sirens COM Table 3 6 3 5 5 Wiring Description of Lock Support 2 groups of lock control outputs serial numbers after the terminals represent corresponding doors Please choose a proper connection mode according to lock type as shown in Figure 3 12 Figure 3 13 and Figure 3 14 Please refer to Table 3 7 for descriptions of wiring terminals Figure 3 12 Figure 3 13 ...

Страница 18: ...5s COM1 NO1 NC2 Intrusion overtime and vandal proof alarm output of door 2 Output time lasts for 15s COM2 NO42 Table 3 8 3 5 7 Wiring Description of Reader 1 door only supports to connect one type of reader 485 or Wiegand Please refer to Table 3 9 for descriptions of wiring terminals corresponding to readers Take Door 1 for example and other readers are the same as door 1 Please refer to Table 3 1...

Страница 19: ...tch is shown in Figure 3 15 Please refer to Function No Description Device Number 1 5 Set device number with binary system The left is the lowest order For example Binary representation 00110 corresponds to 6 in decimal system Speed 6 8 Set the speed All of them are at the bottom transmission speed is 50kb s Only digit 6 is at ON position transmission speed is 80kb s Only digit 7 is at ON position...

Страница 20: ...system The left is the lowest order For example Binary representation 00110 corresponds to 6 in decimal system Speed 6 8 Set the speed All of them are at the bottom transmission speed is 50kb s Only digit 6 is at ON position transmission speed is 80kb s Only digit 7 is at ON position transmission speed is 100kb s Digits 6 and 7 are at ON position transmission speed is 125kb s Table 3 11 ...

Страница 21: ...13 3 7 Reboot Insert a needle into RESET hole and long press the reboot controller ...

Страница 22: ...Reader Wiegand RS485 Communication Port CAN Quantity of Connected Reader 4 groups Working Power Rated power 10V 15V DC rated current 0 75A Real time Monitoring Support Fire Alarm Linkage Support Vandal proof Alarm Support Illegal Intrusion Alarm Support Unlock Overtime Alarm Support Duress Card Setup Support DST and Time Sync Support Online Upgrading Support ...

Отзывы: