The feature of this power supply is that the output voltage signal of constant Voltage circuit
and the output current signal of constant current circuit both are applied to the “GATE”
circuit at the same time. According to requirement of the load, the power supply is
determined to operate in the CV mode or in the CC mode, the automatic switching of the
regulated voltage and the regulated current can solve the problems of over—current
protection of the regulated power supply and the over—voltage protection of the regulated
current power supply.

CONTROL

CONTROL

CONTROL

CONTROL

CIRCUIT:

CIRCUIT:

CIRCUIT:

CIRCUIT:

It is an adjustable reference voltage generator. The output current

and voltage depend on setting the reference voltage.

Model

DH1719A-2

24V-5A

DH1719A-3

32V-4A

DH1719A-4

55V-2A

DH1719A-5

100V-1A

D

C

V

O

L

T

M

E

T

E

R

Range Selection

Accuracy of Voltmeter

±

(0.5%rdg + 3dgts, at 20

±2℃ and < 80%RH

Maximum Allowable Application Voltage

D

C

A

M

M

E

T

E

R

Full Scale (Fixed Range)

Ammeter Accuracy(at20

±2℃ and<80%RH)

±

1rdg + 5dgts

Temperature Coe.

(+400

×

10

-6

)

/℃ full-scale + the accuracy mentioned above

Zero Drift

Not greater than 3dgts within 0-40

Input Fuse

2A

Output Fuse
Weight

8kg

External Dimensions

305(L)

×200(W)×170(H)mm

Reliability of the Instrument

MTBF (

θ

)

5000 hours

Remote

Control

Signal

T

ra

ns

fo

rm

er

Relay Switching and

Aux. Supply Circuit

Output Switch Circuit

Reference Voltage

DC

Remote

Control

Circuit

Voltage

Sampling

Control

Circuit

Rectify

and Filting

Series

Setting

Amplify

Gate

-

CC
Diff
Ampl

+

-

CV
Diff.
Ampl

+

A/D

Conv

AC 220V

Meter Circuit

Current

Sampling

Figure 1

Содержание DH1719A

Страница 1: ...age Current Voltage Current Voltage Current Power Power Power Supply Supply Supply User User User s s s Manual Manual Manual Da Da Dah h hua ua ua Company Company Company of of of Electronic Electroni...

Страница 2: ...ENTS CONTENTS CONTENTS Description Description Description 1 Operating Features 2 Operating Principle 3 Structure Features 4 Applications 5 Maintenance 6 Completeness of the Instrument 7 Storage 8 Gua...

Страница 3: ...this instruction manual before use the power supply 1 1 1 OPE OPE OPER R RATING ATING ATING FEATURES FEATURES FEATURES Model DH1719A 2 24V 5A DH1719A 3 32V 4A DH1719A 4 55V 2A DH1719A 5 100V 1A INPUT...

Страница 4: ...voltage generator The output current and voltage depend on setting the reference voltage Model DH1719A 2 24V 5A DH1719A 3 32V 4A DH1719A 4 55V 2A DH1719A 5 100V 1A DC VOLTMETER Range Selection Accura...

Страница 5: ...it always keeps pre setting value constantly that means this instrument can automatically be converted from constant voltage mode to constant current mode so as to protect the load from over current...

Страница 6: ...TRUCTURE FEATURES FEATURES FEATURES The instrument is designed symmetrically between left and right on the front panel On the upper side there are two digital meters Down the meter there are two indic...

Страница 7: ...lue To keep the voltage position turn off the OUTPUT switch and remove the short bar connect the 1oad press the OUTPUT switch the instrument provides the required current and voltage for the load 4 4...

Страница 8: ...can be control1ed with the voltage setting potentiometer manually on the front panel NOTE NOTE NOTE 5 5 5 Make sure that the output voltage is within the rated output voltage of the instrument 4 6 4...

Страница 9: ...8 4 8 4 8 Paral1el Operation In order to obtain a large output current two or more instruments can be connected in parallel then adjust their output voltage to the same voltage leve1 If differences o...

Страница 10: ...units are connected in paral1eI as shown in Fig 6 4 9 3 4 9 3 4 9 3 Throw R L switch to R position The current setting potentiometer is set to the extreme position 4 9 4 4 9 4 4 9 4 Turn on the OUTPU...

Страница 11: ...are connected to one common line which is connected to a potential line as required 4 10 6 4 10 6 4 10 6 Turn on both POWER and OUTUPUT switches of the master unit and the slave unit NOTE NOTE NOTE 1...

Страница 12: ...Connect an ammeter with accuracy 0 2 to the output termina1 turn on OUTPUT switch and feed the current after feeding the current for approximately 20 minutes calibrate the output current with potentio...

Страница 13: ...nstrument The output terminal is a reference point when the instrument is measured 5 5 5 10 10 10 1 1 1 The voltage of the aux power supply is 15V 5 5 5 10 10 10 2 2 2 The voltage of each measured poi...

Страница 14: ...ition keep the instrument from smoke gas acid alkaline and other corrosive materials be sure not to place the instrument in high temperature and more dust place so as to keep the instrument clean Afte...

Отзывы: