background image

5

2.1

2.1

2.1

2.1

Description

Description

Description

Description

of

of

of

of

Constant

Constant

Constant

Constant

---

-

Voltage

Voltage

Voltage

Voltage

Mode

Mode

Mode

Mode

The reference output voltage circuit is applied to the negative input terminal of a CV error
amplifier, the error voltage from the voltage sampling resistor is applied to the positive input
terminal of the CV error amplifier. The error signals of both voltages are compared each
other and via the gate circuit by amplify then applied to the base of a regulated tube. The
base current of the regulator tube is changed, then a stabilized output voltage can be obtained,

the adjustment of the output voltage is realized by setting the voltage potentiometer on the

front panel.

2.2

2.2

2.2

2.2

Description

Description

Description

Description

of

of

of

of

Constant

Constant

Constant

Constant

---

-

Current

Current

Current

Current

Mode

Mode

Mode

Mode

The reference voltage from the control circuit is applied to the negative input terminal of a

CC error amplifier, the current signal from A/V conversion is applied to the positive input
terminal of the CC error amplifier. Both signals are compared each other and then amplified
to control the base voltage of the regulator tube to reach a stable current output.

2.3

2.3

2.3

2.3

CV/CC

CV/CC

CV/CC

CV/CC

Conversion

Conversion

Conversion

Conversion

---

-

CV

CV

CV

CV

mode

mode

mode

mode

into

into

into

into

CC

CC

CC

CC

mode

mode

mode

mode

Setting CC potentiometer, a preset current value is provided as required, the resistor load is
reduced, the output current is increased. When the output current reaches the preset constant -
current value, the output voltage is reduced. When the power supply is power supply is
operating in the constant-current mode, even of the resistor load value is reduced to zero(in
short circuit state), the output current can not be increased, it always keeps pre-setting value
constantly; that means this instrument can automatically be converted from constant-voltage
mode to constant current mode so as to protect the load from over-current. It is an automatic
CV/CC crossover system type of power supply.

The Figure 2 shows operating points and operating domain related to the load lines. The

preset output voltage is 10V, the limited current is 2A, the operating point in non--load is at A,

when RL=10

Ω

, operating point B, and when RL=5

Ω ,

operating point is at C. The

operating point moves from C to D ,if the resistor load is reduced from RL=5

Ω

to 2.5

Ω

,the

instrument operation is changed from the constant-voltage domain into the constant—current
domain. Point C is called “ Crossover Point” owing to change modes. Wen the resistor load
(RL) is 2.5

Ω,

the output voltage is I. RL=2×2.5=5V.

2.4

2.4

2.4

2.4

CC/CV

CC/CV

CC/CV

CC/CV

Conversion-Constant

Conversion-Constant

Conversion-Constant

Conversion-Constant

Current

Current

Current

Current

Mode

Mode

Mode

Mode

into

into

into

into

Constant-Voltage

Constant-Voltage

Constant-Voltage

Constant-Voltage

Mode

Mode

Mode

Mode

Setting CV potentiometer, a preset value applied as required. When the output voltage
reaches the preset constant voltage value, then output current is reduced.

When the output current is 2A the resistor load is 0

Ω,

operating point is E. While the resistor

load is increased to 2.5

Ω,

the operating point moves from E to D. When the operating point

is increased to 5

Ω

, the operating point moves from D to C. While the resistor load further is

increased to 10

Ω ,

the operating point moves from C to B. In this case, the instrument is

converted to the constant-voltage domain. When the resistor load is increased continuously
to an open circuit, the operating point moves from B to A . Generally, the voltage applied to
the load is not more than the preset voltage. The instrument can convert from the CC mode
to the V mode in order to protect the load. The point C serves as a crossover point.

Содержание DH1715A

Страница 1: ...ated Regulated Voltage Current Voltage Current Voltage Current Power Power Power Supply Supply Supply User User User s s s Manual Manual Manual Da Da Dah h hua ua ua Company Company Company of of of E...

Страница 2: ...ENTS CONTENTS CONTENTS Description Description Description 1 Operating Features 2 Operating Principle 3 Structure Features 4 Applications 5 Maintenance 6 Completeness of the Instrument 7 Storage 8 Gua...

Страница 3: ...ion manual before use the power supply 1 1 1 OPE OPE OPER R RATING ATING ATING FEATURES FEATURES FEATURES Model DH1715A 3 32V 2A DH1715A 5 32V 3A INPUT Input Power Supply 220V 10 50Hz 5 Power Dissipat...

Страница 4: ...ustable reference voltage generator The output current and voltage depend on setting the reference voltage Model DH1715A 3 32V 2A DH1715A 5 32V 3A DC VOLTMETER Range Selection Accuracy of Voltmeter 0...

Страница 5: ...e increased it always keeps pre setting value constantly that means this instrument can automatically be converted from constant voltage mode to constant current mode so as to protect the load from ov...

Страница 6: ...right on the front panel On the upper side there are two digital meters A switch for output in the middle of the panel is mounted There are four knobs in line as voltage potentiometer of each circuit...

Страница 7: ...d current and voltage for the load 4 4 4 4 4 4 When turn off the power supply first should turn off the OUTPUT switch then turn off the POWER switch 4 5 4 5 4 5 Remote Control CV Output The output vol...

Страница 8: ...ion against noise NOTE NOTE NOTE 4 4 4 When the R L remote local switch is thrown to the L position the output voltage can be control1ed with the voltage setting potentiometer manually on the front pa...

Страница 9: ...The total series vo1tage should not exceed 200V 4 8 4 8 4 8 Paral1el Operation In order to obtain a large output current two or more instruments can be connected in parallel then adjust their output v...

Страница 10: ...s are connected in paral1eI as shown in Fig 6 4 9 3 4 9 3 4 9 3 Throw R L switch to R position The current setting potentiometer is set to the extreme position 4 9 4 4 9 4 4 9 4 Turn on the OUTPUT swi...

Страница 11: ...nnected to a potential line as required 4 10 6 4 10 6 4 10 6 Turn on both POWER and OUTUPUT switches of the master unit and the slave unit NOTE NOTE NOTE 1 For the remote control operation it is neces...

Страница 12: ...urrent after feeding the current for approximately 20 minutes calibrate the output current with potentiometer RV6 so the indication on the digital meter is the same as the standard ammeter 5 6 5 6 5 6...

Страница 13: ...s measured 5 5 5 10 10 10 1 1 1 The voltage of the aux power supply is 15V 5 5 5 10 10 10 2 2 2 The voltage of each measured point on the PC board V2 6 1v REFV 0 10V REFC 0 10V CCAMP 0 10V When operat...

Страница 14: ...other corrosive materials be sure not to place the instrument in high temperature and more dust place so as to keep the instrument clean After delivery within 18 months if the users abide by the regul...

Отзывы: