Web Interface
62
Parameter
Description
Unlock Period
The time amount for which the lock stays open after unlock, and
the unit is second.
Check Door Sensor
Signal Before Lock
Select the
Check Door Sensor Signal Before Lock
check box to
enable alarm function, and If the unlock time exceeds the
Door
Sensor Check Time
, the door sensor alarm is triggered, and the
alarm will be sent to the management center.
Door Sensor Check
Time
Open Door
Command
You can connect a third-party phone such as SIP phone to your
VTO, and use the command to open the door remotely.
Issue Card Password
This password can be used to issue new card.
This password is only for admin people or engineer.
It is 002236 by default.
Project Password
It can be used to go to the engineering interface, and it is 888888
by default.
Project password is only for admin people or engineers.
Lift Control Protocol
Select
Lift Control Protocol
and
Lift Control Enable
to enable
the lift control function, and then you can configure the floors that
lift users can go to.
Lift Control Enable
Baud Rate
Enter the baud rate of the third party 485 device that you need.
New Unlock
Password
Select
Common Password Enable
, then configure unlock
password, and then all the residents in this unit can open the door
with this password.
New Unlock
Password Confirm
Common Password
Enable
New Menace
Password
Select
Menace Password Enable
to configure duress password
function.
Once the duress password is used, the alarm is triggered, and it
will be sent to the management center.
New Menace
Password Confirm
Menace Password
Enable
Auto Snapshot
Select
Turn on
, and then the system takes 2 snapshots when
unlocking, and then upload to the FTP.
Click
OK
to save.
Step 3
7.3.3 Talk Manager
Upload the snapshots and the video and audio messages to the FTP. Make sure the FTP is
properly configured.
This section introduces how to configure auto snapshot and how to leave messages during
phone call.