background image

 

 

Thermal Hybrid Speed Dome  

Quick Start Guide 

 

Version 2.0.0 

Содержание DH-TPC-SD8620-B

Страница 1: ...Thermal Hybrid Speed Dome Quick Start Guide Version 2 0 0 ...

Страница 2: ...ace and Intension 6 3 1 2 About cable 6 3 2 Install SD Card and Reset Device Optional 6 3 3 Installation Steps 7 3 3 1 Wall mounted Installation 7 3 3 2 Hang mounted Installation 9 3 3 3 Corner mounted Installation 10 3 3 4 Pole mounted Installation 11 4 DEVICE CONFIGURATION 13 4 1 Device Initialization 13 4 2 Modify IP Address 14 4 3 Live Video 14 4 4 Alarm Setup 15 5 APPENDIX Ⅰ LIGHTENING PROTEC...

Страница 3: ...Welcome Thank you for purchasing our thermal hybrid speed dome ...

Страница 4: ... the following safeguards and warnings carefully before you install or use the product Cybersecurity Recommendations Mandatory actions to be taken towards cybersecurity 1 Change Passwords and Use Strong Passwords ...

Страница 5: ... reduces the risk of outsiders being able to guess which ports you are using 3 Enable HTTPS SSL Set up an SSL Certificate to enable HTTPS This will encrypt all communication between your devices and recorder 4 Enable IP Filter Enabling your IP filter will prevent everyone except those with specified IP addresses from accessing the system 5 Change ONVIF Password On older IP Camera firmware the ONVI...

Страница 6: ...d do so only temporarily for tracing and testing purposes only 12 Multicast Multicast is used to share video streams between two recorders Currently there are no known issues involving Multicast but if you are not using this feature deactivation can enhance your network security 13 Check the Log If you suspect that someone has gained unauthorized access to your system you can check the system log ...

Страница 7: ...ion engineer or maintenance engineer shall have qualification certificate for work at height The installation engineer or maintenance engineer shall have the basic knowledge and operation technique for low voltage cable layout and low voltage electronic cable connection Please read the installation manual carefully and keep it well for future reference We are not liable for any problems caused by ...

Страница 8: ...ecoverable damage to the thermal imaging detector What s worse it may cause severe damage to the detector 5 Avoid oil stain and kinds of chemicals tarnishing and damaging the lens surface 6 Store the device in a cool and dry place where there is ventilation but no intense electromagnetic field 7 Violent vibration or crash is not allowed during transportation and application 8 Before you connect th...

Страница 9: ...6 Installation Environment Requirement This series thermal hybrid dome should be installed in a cool dry place away from direct sunlight inflammable explosive substances and etc This series product shall be away from the strong electromagnetism radiant please keep it away from wireless power TV transmitter transformer and etc 7 Daily Maintenance Please use the soft cloth to clean dust on the shell...

Страница 10: ...or written notice The product updates might cause some differences between the actual product and the Guide Please contact the customer service for the latest program and supplementary documentation There still might be deviation in technical data functions and operations description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader softwa...

Страница 11: ...rovide reasonable protection against harmful interference in a commercial environment Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense For class B device these limits are designed to provide reasonable protection against harmful interference in a residential installation ...

Страница 12: ...opening the packing box and confirm if the accessories in the box are in accordance with those on the list Please refer to Table 1 1 for more details about the list Accessory Name Quantity Thermal Hybrid Speed Dome 1 Power Adapter 1 Quick Start Guide 1 Installation Accessory Bag 1 Table 1 1 ...

Страница 13: ...eceive analog audio signal from sound pick up and other devices AUDIO OUT Audio output port RCA Output audio signal to speaker and other devices AUDIO GND Audio ground terminal Grounded terminal 4 LAN Network port Ethernet port Connect to standard Ethernet cable 5 VIDEO OUT Analog video output BNC Generally it outputs analog video signal it can connect to TV monitor to check image 6 RS485 RS485 Po...

Страница 14: ...ALARM _GND Grounded terminal Table 2 2 Note Restore factory default parameters After the device is powered on the connector is not plugged into the network port plug the connector into the network port when the device starts normally and it has access to visit WEB interface plug out the connector after waiting for about 5 seconds the device will reboot automatically and restore factory default set...

Страница 15: ...Figure 2 2 Please refer to Figure 2 3 for the dimension of wall mounted bracket The unit is mm inch Figure 2 3 Please refer to Figure 2 4 for the dimension of hang mounted bracket The unit is mm inch ...

Страница 16: ...e 2 4 Please refer to Figure 2 5 for the dimension of corner mounted bracket The unit is mm inch Figure 2 5 Please refer to Figure 2 6 for the dimension of pole mounted bracket The unit is mm inch Figure 2 6 ...

Страница 17: ...rnational Model Max Transmission Distance Ft M RG59 U 750Ft 229M RG6 U 1 000Ft 305M RG11 U 1 500Ft 457M Table 3 1 Select required service cable Caution It is recommended to install the matched power within 5m from the device if it is allowed but if not then it needs to extend the power supply cable but it has to guarantee the voltage of the device input port thermal hybrid dome output cable is no ...

Страница 18: ...firmly Caution Please check if the waterproof ring is installed properly before closing the cover otherwise it will affect the waterproof performance of the device 3 3 Installation Steps The hybrid speed dome supports four installation modes which are wall mount hang mount corner mount and pole mount Warning It shall avoid device parts and tools etc falling from high altitude during installation i...

Страница 19: ... the external cable well according to the requirements 1 Connect the corresponding power video output RS485 control cable alarm input and output and other ports well according to requirements and then use insulated rubber tape to twine the connection joint well to make it waterproof Note The video port is covered with heat shrinkable tube with high shrinkage ratio it needs to heat and shrink the t...

Страница 20: ...rk port and rotate it clockwise to lock the network port and waterproof connector firmly 4 Put the waterproof locking cover on the main body of waterproof connector and rotate it clockwise to lock the waterproof connector and waterproof locking cover firmly 3 3 2 Hang mounted Installation Note The adjustable range of hang mounted bracket length is 200mm default and 400m optional it only needs to r...

Страница 21: ...ories bag for more details 4 Check if the speed dome is firmly fixed and then device installation is completed which is shown in Figure 3 4 Step 2 Connect the external cable well according to the requirements Please refer to step 2 of 3 3 1 Wall mounted Installation for more details Step 3 Optional Install waterproof connector for network port Please refer to step 3 of 3 3 1 Wall mounted Installat...

Страница 22: ...leted which is shown in Figure 3 5 Step 2 Connect the external cable well according to the requirements Please refer to step 2 of 3 3 1 Wall mounted Installation for more details Step 3 Optional Install waterproof connector for network port Please refer to step 3 of 3 3 1 Wall mounted Installation for more details 3 3 4 Pole mounted Installation Note It is equipped with 5 inch hose clamp by defaul...

Страница 23: ...ut the cable into the wall mounted bracket use stainless screws to fix the speed dome on the bracket 5 Pull the cable through pole mounted bracket and then use screws to fix the device and wall mounted bracket on the pole mounted bracket 6 Check if the speed dome is firmly installed and then device installation is completed which is shown in Figure 3 6 Note Check if the hoop is firmly tightened af...

Страница 24: ...s are in the same network segment Step 1 Open IE browser input camera default IP address in the address bar and then press Enter Note The factory default IP address is 192 168 1 108 The system will display the interface of Device Initialization after it is successfully connected which is shown in Figure 4 1 Figure 4 1 Step 2 Set the login password of admin please refer to Table 4 1 for more detail...

Страница 25: ...ser is admin the password is set during device initialization Step 2 Select Setup Network TCP IP and the system will display the interface of TCP IP which is shown in Figure 4 2 Figure 4 2 Step 3 Configure relevant info of IP address click Save 4 3Live Video Note Different devices might have different WEB interfaces the figure in this document is just for reference please refer to the document WEB...

Страница 26: ...resh automatically after plug in installation is completed then live video will show up Figure 4 3 4 4Alarm Setup Note Some devices do not support alarm function the chapter cannot be applied It has to cut off power first when connecting cables Alarm input and output connection description Step 1 Connect alarm input device to alarm input port of I O cable Step 2 Connect alarm output device to alar...

Страница 27: ...nding NO and NC according to the high and low level signal generated by alarm input device when alarm occurs Alarm output is corresponding to the alarm output port of device I O cable Figure 4 4 Alarm input and output figures Figure 4 5 Alarm input input signal is idle or grounded the device can collect different states of alarm input port Input signal is connected to 3 3V or idle device collects ...

Страница 28: ...Figure 4 6 Alarm output port ALARM_OUT and ALARM_COM form a switch which can be used to provide alarm output Normally the switch is on the switch will be off when there is alarm output ...

Страница 29: ...nects one point to the earth Open floor cable layout is forbidden In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install additional high power thunder protection device or lightning rod The thunder protection and earth of the outdoor device and cable shall be considered in the building whole thunder protection and conf...

Страница 30: ...are here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please refer to the final explanation of us Please visit our website or contact your local service engineer for more information ...