Dahua DEE1010B Скачать руководство пользователя страница 4

                                                                           

 

 

1

1.

 

General Introduction  

1.1

 

Overview 

The access and control extension module is a door extension module controller for 86mm×86mm 

po

wer box.  The extension module can work independently   with the access control, video door 

phone and management platform. It can easily realize A&C extension function. The module 

communicates with the upper-level device via RS485 BUS to realize A&C function and support 

swipe card function with the card reader. It has one-channel door sensor signal input, one-

channel lock/unlock input and one-channel door sensor control output and etc. The door lock 

supports NO/NC. 

 

Access and control extension module can work with the management platform to issue card, 

delete card and open door remotely. The module can upload the swipe card information, door 

lock/unlock information, alarm information to the management center to realize the realtime door 

surveillance. Besides, the management center can set the A&C parameters and set customized 

swipe card period and time sync. After grant the card rights, it can swipe the card or use the 

button to open the door without the main controller.  

 

1.2

 

Typical Connection  

Please refer to the following figure for typical connection information. See Figure 1. 

 

Figure 1

 

Содержание DEE1010B

Страница 1: ...Access and Control Extension Module User s Manual Version 1 0 0 ...

Страница 2: ...here should conform to your local electrical safety codes We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation Do not apply power to the device before completing installation UPS is recommended if you want to use the device even in power failure Always follow the instruction guide the manufacturer recommended Be sure to use all ...

Страница 3: ...ii Table of Contents 1 General Introduction 1 1 1 Overview 1 1 2 Typical Connection 1 2 Installation 2 3 FAQ 3 4 Specifications 4 ...

Страница 4: ...nput and one channel door sensor control output and etc The door lock supports NO NC Access and control extension module can work with the management platform to issue card delete card and open door remotely The module can upload the swipe card information door lock unlock information alarm information to the management center to realize the realtime door surveillance Besides the management center...

Страница 5: ...mation SN Name Function 1 12V Power 2 GND Power GND 3 485A Host 485A 4 485B Host 485B 5 POWER Power indicator light 6 RUN Running indicator light 7 UNLOCK Unlock indicator light 8 NC Lock normal close 9 NO Lock normal open 10 COM Lock COM 11 BUTTON Lock unlock button 12 BACK Lock sensor feedback 13 GND Ground 14 485B Card reader 485B 15 485A Card reader 485A ...

Страница 6: ... device is damaged The device and the management center can not communicate Check 485 communication cable connection Click the lock unlock button can not open the door Check the lock unlock button and the device connection After open the door the lock remains open for a long time Check the door is close or not The door sensor connection is OK or not If there is no door sensor please contact the ma...

Страница 7: ...Upload Card No Support Upload Door Open Information Support Upload Alarm Support Others Power Supplying DC12V 10 Power Consumptions Standby 0 5W Work 1W Working Environment 10 60 10 95 RH Dimensions 58mm 51mm 24 5mm L W H Weight 0 56kg Note This manual is for reference only Slight difference may be found in the user interface All the designs and software here are subject to change without prior wr...

Страница 8: ...5 Please visit our website or contact your local service engineer for more information ...