40
Change alarm linkage parameters
Table 3-2
Alarm linkage parameter description
Parameter
Description
Alarm Input
You cannot modify the value. Keep it default.
Name
Enter a zone name.
Alarm Input Type
If alarm input type of the alarm device you purchased is
NO
, then you
should select
NO
; otherwise you should select
NC
.
Fire Link Enable
If fire link is enabled the access controller will output alarms when fire
alarms are triggered. The alarm details will be displayed in the alarm
log.
Alarm intput and access link are NO by default if fire link is enabled.
Access Link Enable
If enabled, the access controller will be normally on or normally closed
when there are input alarm signals.
Channel Type
There are two options: NO and NC.
Click
OK
, and then the configuration is completed.
The configuration on the web will be synchronized with the configuration in the client if
the access controller is added to a client.
3.5.2
Alarm Log
You can view the alarm type and time range in the
Alarm Log
interface.
Log in to the web interface.
Select
Alarm Linkage > Alarm Log
.