Step 1. Select SETUP>Event>Report Mode. See Figure 4- 17.
Figure 4- 17
Step 2. Select network priority and report mode.
PRIORITY: apply to TCP/IP protocol transmission, by setting network priority; you can select
to transmit via wired Ethernet or 3G/4G wireless network transmission.
Setup
Note
Wired only
Event via wired Ethernet network transmit to alarm
center
3G/4G network
Event via 3G/4 wireless network transmit to alarm
center
Wired network priority,
failed convert to 3G/4G
network
Event priority through a wired Ethernet transmission
to the central station, if the cable network failure,
switching to 3G / 4G network transmission; if a wired
network is restored, then the next alarm event
switches to the wired network.
Report mode: Via report mode config, you can select transmit event via Ethernet or telephone
line.
Setup
Note
Not report
Under this mode, event will not be reported to
network and call center
Report to network center 1
only
Evert will be reported to network center 1
(
auto
register, direct connect IP, SDKDemo, WEB
)
Dial call center 1 only
Event will be reported to call center 1
(
center
config see Ch 4.10.1
)
Dial call center 1 and if
failed, dial 2
Event will be reported to call center 1, if failed,
dial call center 2
Dial call center 1 and 2 at
the same time
Event will be reported to call center 1 and 2
Sent to network center 1, if
failed, send to call center 1
Event will be reported to network center 1, if
failed, event will be sent to call center 1
Send to network center 1 Event will be reported to both network center 1