Alarm Control Panel Installer Manual
8
Supports abnormality alarm, including network disconnected alarm, PSTN fault alarm, tampering
alarm, low battery alarm, battery loss alarm, power loss alarm, and keyboard faults alarm.
In-field firmware upgradable.
App-based system control through DMSS.
Terms and Definitions
1.3
Refer to the terms and definitions that are used in the Manual as below.
Table 1-1 Terms and definitions
Term
Definition
Area
The 8 Areas that can be armed.
Zone
Protection zones under Area.
Partition
The scope of Partition is larger than Zone and under Area.
Numeric key
Key 0
–9 on the Keypad.
Function key
The other keys except Numeric keys, such as ESC and ENTER.
Key combination
+ Numeric key.
User Menu
Menus programmed by the User.
Installer Menu
Menus programmed by the TECHNICIAN.
Access Code
A specified code, from 4 to 6 digits, that allows the user to operate the
Keypad.
TECHNICIAN
A person that is authorized to access the Installer Menu to program
the system.
1EOL
The detector type can be NO or NC, and returns two status: Normal
and Alarm (short circuit and broken circuit are considered to be Alarm
status).
2EOL
The detector type can be NO or NC, and returns four status: Normal,
Alarm, Tamper, and Short Circuit prevention.
3EOL
The detector type can be NO or NC, and returns five status: Normal,
Alarm, Tamper, Anti-masking, and Short Circuit prevention.
Содержание ARC3008C
Страница 1: ...Alarm Control Panel Installer Manual V1 0 1 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD ...
Страница 16: ...Alarm Control Panel Installer Manual 15 Wiring of detectors Figure 1 6 ...
Страница 17: ...Alarm Control Panel Installer Manual 16 Keypad connection Figure 1 7 ...
Страница 67: ...Alarm Control Panel Installer Manual 66 Vocal message flow Figure 1 36 ...