Appendix Figure 7-2
Multiple-point ground
Mixed ground: The mix ground consists of the feature of the one-point ground and multiple-
point ground. For example, the power in the system needs to use the one-point ground mode
while the radio frequency signal requires the multiple-point ground. So, you can use the following
figure to earth. For the direct current (DC), the capacitance is open circuit and the circuit is one-
point ground. For the radio frequency signal, the capacitance is conducive and the circuit adopts
multiple-point ground.
Appendix Figure 7-3
Mixed ground
When connecting devices of huge size (the device physical dimension and connection cable is big
comparing with the wave path of existed interference), then there is possibility of interference when
the current goes through the chassis and cable. In this situation, the interference circuit path usually
lies in the system ground circuit.
When considering the earthing, you need to think about two aspects: One is the system compatibility,
and the other is the external interference coupling into the earth circuit, which results in system error.
For the external interference is not regular, it is not easy to resolve.
Appendix 7.3
Thunder Proof Ground Method in the Monitor
System
The monitor system shall have sound thunder proof earthing to guarantee personnel safety and
device safety.
The monitor system working ground resistance shall be less than 1 Ω.
The thunder proof ground shall adopt the special ground cable from the monitor control room
to the ground object. The ground cable adopts copper insulation cable or wire and its ground
Содержание DH-XVR1B -I Series
Страница 1: ...AI Digital Video Recorder User s Manual V2 2 0 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...
Страница 24: ...User s Manual 14 Connect cables Put back the cover Put back cover Fasten the screws Fasten screws...
Страница 112: ...User s Manual 102 Analog channel Digital channel Configure the settings for the image parameters...
Страница 187: ...User s Manual 177 Details Click Register ID Register ID Click to add a face picture...
Страница 238: ...User s Manual 228 Details Click Register ID Register ID Click to add a face picture...
Страница 314: ...User s Manual 304 Main stream Sub stream...
Страница 317: ...User s Manual 307 Version 1 Version 2...
Страница 362: ...User s Manual 352 Legal information...
Страница 370: ...User s Manual 360 Abbreviations Full term VBR Variable Bit Rate VGA Video Graphics Array WAN Wide Area Network...
Страница 388: ...User s Manual 378 Appendix Figure 7 7 Check neutral cable connection...
Страница 394: ...User s Manual...