background image

 

Cybersecurity Recommendations

  

IX 

 

Connect IP Cameras to the PoE Ports on the Back of an NVR 

 

Cameras connected to the PoE ports on the back of an NVR are isolated from the 
outside world and cannot be accessed directly. 

 

Isolate NVR and IP Camera Network 

 

Ensure that the network for the NVR and IP cameras should not be the same network 
as a public computer network. Separate networks prevent unauthorized users 
accessing the same network the security system. 

 

Secure Auditing 

 

Check online users regularly to ensure unauthorized accounts are not logged in to a 
device. 

 

Check the equipment log to access the IP addresses used to login to devices and 
their key operations. 

 

Содержание 22204UENI-W

Страница 1: ...22204UENI 22204UENI W Quick Installation Guide V1 0 1 Dahua Technology Co Ltd ...

Страница 2: ...perty damage data loss lower performance or unpredictable result NOTE Provides additional information as the emphasis and supplement to the text Revision History No Version Revision Content Release Time 1 V1 0 0 First Release January 2019 2 V1 0 1 Revised for North America July 2019 Privacy Protection Notice As the device user or data controller you may collect personal data such as face images fi...

Страница 3: ...ost digital information Dahua recommends multiple redundant recording systems and adoption of backup procedure for all data All trademarks registered trademarks and the company names in the Guide are the properties of their respective owners Please visit our website contact the supplier or customer service if there is any problem occurred when using the device Contact the supplier or customer serv...

Страница 4: ...Consult the dealer or an experienced radio TV technician for help Legal Notices Copyright This user guide is 2017 Dahua Technology Company LTD This user guide is the intellectual property of Dahua Technology Company LTD and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treate...

Страница 5: ...Do not overload outlets and extension cords which may cause fire or electrical shock Do not place the camera near or in a place where the camera may contact overhead power lines power circuits or electrical lights Ensure power conforms to SELV Safety Extra Low Voltage and that the limited power source is rated AC 24V as specified in IEC60950 1 Power supply requirement is subject to the device labe...

Страница 6: ...netic radiation or unstable lighting Do not use the device in the corrosive environment such as high salt fog area sea beach and coastal area acid gas environment and chemical plants Do not use the device in applications with strong vibrations such as in boats and vehicles Never push objects of any kind into this unit through openings as they may touch dangerous voltage points or cause a short cir...

Страница 7: ...wer to gently remove the dirt Stained with grease or fingerprints Use a soft cloth to wipe gently the water droplet or the oil from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to outside Change the cloth several times to ensure the dome cover is clean WARNING Modify the default password after login Use att...

Страница 8: ...ccount name or the account name in reverse order Do not use sequential characters such as 123 abc etc Do not use repeated characters such as 111 aaa etc Change Default HTTP and TCP Ports Change default HTTP and TCP ports for systems These are the two ports used to communicate and to view video feeds remotely These ports can be changed to any set of numbers between 1025 and 65535 Avoiding the defau...

Страница 9: ...to perform their job Disable Unnecessary Services and Choose Secure Modes Turn off specific services such as SNMP SMTP and UPnP to reduce network compromise from unused services It is recommended to use safe modes including but not limited to the following services SNMP Choose SNMP v3 and set up strong encryption passwords and authentication passwords SMTP Choose TLS to access a mailbox server FTP...

Страница 10: ...nd IP Camera Network Ensure that the network for the NVR and IP cameras should not be the same network as a public computer network Separate networks prevent unauthorized users accessing the same network the security system Secure Auditing Check online users regularly to ensure unauthorized accounts are not logged in to a device Check the equipment log to access the IP addresses used to login to d...

Страница 11: ... Installation and Configuration 2 Framework and Dimension 2 Wiring 3 Locally Storing Data 3 3 Camera Installation 4 Preparing the Camera 4 3 1 1 Insert a Micro SD Card 5 Mounting the Camera to a Ceiling 5 4 Network Configuration 8 Network Protocols 8 Modifying the IP Address 9 Using the ConfigTool 9 Accessing the Web Interface 10 Configuring Local SD Card Recording 11 ...

Страница 12: ...tative The original packing carton is the safest container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please refer to the enclosed CD for more details to view the detailed User s Manual and for configuration software Parts List Package Item Quantity Network PTZ Camera 1 Screws 3 Wall Anchors 3 Weatherproof Eth...

Страница 13: ...figuration 2 2 Installation and Configuration Framework and Dimension Use this process to plan install and configure the security network and the IP devices Figure 2 1 22204UENI Dimensions Figure 2 2 22204UENI W Dimensions ...

Страница 14: ... is better suited for constant recording Lower grade SD cards meant for multimedia applications will at times have questionable quality and reliability Recording to the SD card is first in first out FIFO The camera deletes the oldest first entry as new storage requirements arise The camera does not signal nor make an indication when data is deleted Storage time is dependent on a variety of factors...

Страница 15: ...A70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local country codes for all other countries Branch circuit protection incorporating a 20 A 2 pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation A readily accessible 2 pole disconnect device with a contact separation of at least 3 mm must be ...

Страница 16: ...The Micro SD card slot is located on the ISP board above the camera module Figure 3 1 Micro SD Card Installation Open the cover for the SD Card slot Insert the Micro SD Card into the Micro SD Card slot Replace the cover Mounting the Camera to a Ceiling ...

Страница 17: ...e pedestal with the pre drilled perimeter holes Secure the pedestal to the ceiling with the three screws Use the hex wrench to secure the three screws in external enclosure to the pedestal Attach the waterproof network connector if the camera is used outdoors a Place the wide side of the rubber ring onto the end of the network cable extending out from the camera b Pull the waterproof cable end wit...

Страница 18: ... the mount adapter quick installation port Slowly push the dome into the wall mount Insert the three 3 stainless steel set screws into the corresponding holes on the wall mount flange and tighten to dome flange with the hex wrench Ensure the safety tether is attached to wall mount and to the camera ...

Страница 19: ...y manage and automate the assignment of IP addresses DHCP should only be enabled if using dynamic IP address notification or if the DHCP can update a DNS server TFTP The Trivial File Transfer Protocol is a simple lock step File Transfer Protocol which allows a client to get from or put a file onto a remote host TFTP lacks security and most of the advanced features offered by more robust file trans...

Страница 20: ...Dahua supplies the ConfigTool to access and to modify the network settings of a device Refer to the Operation Manual available on the CD included with the camera or on Dahuasecurity com for complete information Notes Ensure that the network parameters of each camera is available before starting configuration The ConfigTool supports those cameras that are part of the same network that as the comput...

Страница 21: ...devices may have different Web interfaces the figures below are for reference only and may not represent the Web Interface for your camera Refer to the Web Operation Manual included on the CD shipped with the camera for more details Launch Internet Explorer and type the modified camera IP address in the address bar Internet Explorer opens the Login page Type the Username and Password for the camer...

Страница 22: ...he Local tab to view the used capacity and the total capacity of the Micro SD card Expand the Event menu located at the left of the Web interface then select the Abnormality page to set alarms related to the Micro SD card The contains the following Micro SD card alarm options No SD Card Device triggers an alarm if the device does not contain a Micro SD card Capacity Warning Device triggers an alar...

Страница 23: ...ay the alarm relay output 10 s to 300 s Check the Send Email box to send an email to a specified user after the device triggers an alarm Set the capacity limit for the Micro SD Card available with the Capacity Warning event type The device triggers an alarm once the amount of data on the card surpasses this limit ...

Страница 24: ...e CA 92618 Tel 949 679 7777 Fax 949 679 5760 Support 877 606 1590 Sales sales usa dahuatech com Support support usa dahuatech com 2019 Dahua Technology USA All rights reserved Design and specifications are subject to change without notice ...

Отзывы: