8.Features
© China Daheng Group, Inc. Beijing Image Vision Technology Branch 48
Figure 8-34 Reverse Y enabled
Figure 8-35 Reverse X and Y enabled
The alignment of the Bayer format does not change when the camera is using the reverse feature (VEN-
161-61U3 cameras have no color models).
Camera models that support this feature:
Model
VEN-161-61U3M-(M01/M05/M06)
8.3.9.
User Data Area
The user data area is a FLASH data area reserved for the user, and the user can use the area to save
algorithm factors, parameter configurations, etc.
The user data area is 16K bytes and is divided into 4 data segments, each of which is 4K bytes. The user
can access the user data area through the API interface. The data is saved to the camera flash area
immediately after being written, and the data will not disappear after the camera is powered off.
Camera models that support this feature:
Model
VEN-161-61U3M-(M01/M05/M06)
8.4.
Image Transmission
8.4.1.
Calculate Frame Rate
1)
Frame Period
You can calculate the frame period of the VEN-U3 series camera by the following formula:
𝑇
𝑓
= Max (
ImageSize ∗ 10
6
BandWidth
USB
,
ImageSize ∗ 10
6
DeviceLinkThroughputLimit
,
T
acq
,
T
exp
)
Among them:
ImageSize =
Width ∗ Height ∗ Pix 84
𝑇
𝑓
: The camera's frame period, unit: μs.