background image

DAGON Lighting

 

SPM-12 – controller 

DMX-512 – 12 OUT DC / PWM

 

 

 

6

Tabel 1. 

 

List of configuration codes and their associated control functions for the SPM-12 driver. 

 

Code 

Function / Parameter / Value 

 

001 … 512  DMX address of SPM-12 controller 

 

610 

SPM-12 work as without DMX-512 signal  - active codes 630 ... 635 

611 

Outputs work Q1-Q12 in PWM mode:  

DMX = 0..255  –  Q = PWM 0..100%

 

612 

Outputs work Q1-Q12 in DC mode:  

DMX = 0..127 - Q = OFF  /  DMX = 128..255 - Q = ON

 

 

620 

DIMMER OFF – function DIMMER is turn off 

621 

DIMMER ON 1 – function DIMMER is active  –  0=min 255=max brightness 

622 

DIMMER ON 2 – function DIMMER is active  –  0=max 255=min brightness 

 

630 

No reaction for lack of DMX signal – keeping the last value of outputs Q1-Q12 

631 

After lack of DMX signal – display effect 

632 

After lack of DMX signal – turn off all of outputs:  Q1-Q12 = OFF 

633 

After lack of DMX signal – 20% PWM signals on Q1-Q12 

634 

After lack of DMX signal – 50% PWM signals on Q1-Q12 

635 

After lack of DMX signal – turn on all of outputs:  Q1-Q12 = ON 

 
 
 

2.3. Description of configuration codes of SPM-12. 
 

Basic steering codes which need to be set-in to SPM-12 controller is the address of DMX 

controller, it means one code form range 

001 to 512

. When user enter any code from 001 to 

512  it  will  cause  automatic  change  the  previous  value  form  this  range  and  memorize  new 
address od DMX in memory controller. 

DMX address indicate number of channel in steering signal of DMX-512, from where the 

steering datas of outputs Q1-Q12 are collect. The controller’s Q1-Q12 outputs will be reacting 
on  the  values  from  DMX  channels 

numbered  sequentially  from 

address DMX 

to

 

address DMX + 11. 

 

Second important parameter is the manner of output’s work Q1-Q12. 

These outputs can be configured to work in PWM mode –

 code 611 

or in bistable DC status 

(ON/OFF) – 

code 612

 

In PWM mode, the outputs Q1-Q12 PWM waveforms are generated by filling proportional to 
the value of DMX channel corresponding to output: 

- PWM = 0..100% of the value of DMX channel = 0..255 

 

In bistable mode DC (ON/OFF) outputs Q1-Q12 have only two states: 

- OFF - turn off, when DMX value of output steering channels is from 0 to 127 range 
- ON -  turn on, when DMX value of output steering channels is from 128 to 255 range

 

 

After  enter  the 

code  610

  the  SPM-12  will  not  react on DMX-512 signal even when this 

signal pass on in DMX+ and DMX- inputs. Reaction of SPM-12 controller will be the same 
as in lack of DMX-512 signal on inputs – see description codes 630...635. 
 

Содержание SPM-12

Страница 1: ...DMX 512 controller 12 OUT DC PWM MANUAL INSTRUCTION Firma DAGON 64 100 Leszno Jackowskiego 24 Street mob 00 48 664 092 493 dagon iadagon pl www iadagon pl www dagonlighting pl DAGON Lighting Product...

Страница 2: ...X address SPM 12 driver 5 2 3 Description of configuration codes of SPM 12 6 2 4 Example configuration of the controller SPM 12 7 3 Safety and correct conditions of using SPM 12 controller 8 4 SPM 12...

Страница 3: ...f power On the Figure 1 the proper way of wiring the power supply and receiver LED diodes to control SPM 12 is shown Remember to pick up the power cables of sufficient diameter relative to a flowing c...

Страница 4: ...of code is from 0 to 9 Every press is signalize by a short blinking of green diode After set in the second digit button CODE need to be press one more time The yellow diode will blink and it is the si...

Страница 5: ...of first digit of DMX 512 address Green diode will blink as many times as the first digit of DMX address is from 0 to 5 Than yellow diode blinks once light off for half a second and light on again wh...

Страница 6: ...X controller it means one code form range 001 to 512 When user enter any code from 001 to 512 it will cause automatic change the previous value form this range and memorize new address od DMX in memor...

Страница 7: ...dividual codes is described in Table 1 The demonstration effect for the code 631 is smoothly dimming and lightening of LEDs connected to the outputs Q1 Q12 in an alternate driver for the outputs of od...

Страница 8: ...ects what may cause the stillness effect on the rotating equipment s which is light by impulse lights it may cause dangerous situation for life and healthy 4 SPM 12 Technical data Power supply 9 24V D...

Отзывы: