Dafra RRT5212 Скачать руководство пользователя страница 2

1

2

3

4

5

6

approx 1.0 mm gap

switch up

Adjust anvil so that 1 thread
of tool mandrel is showing.
Tighten anvil lock nut.

Hold forward
handle still

Rotate rear handle
anti clockwise until 
rivnut is set in
work piece.

Note; gap increases as rivnut is set. 
Use stoke guage for consistant setting

switch
down

Hold forward
handle still

Rotate rear handle
clockwise one turn.
Anvil will release
rivnut.

Rotate splined knob anti clockwise 
to remove mandrel from work piece.

Return to position 1