11
Flow Meter User's Manual
Application
Water treatment system
SENSOR INSTALLATION IS CARRIED OUT BY THE INSTALLER
Installation of power supply batteries
Slide off the battery compartment cover from the side of the flow meter housing, slide out the basket
and insert the into it two AA alkaline batteries maintaining the correct polarity. Then slide the basket and
replace the cover. The capacity of two AA alkaline batteries is enough for two years of normal use.
Programming the filter performance monitoring
Press the "PROG" button, "PROG" will flash on the LCD display. Then press "RESET" to select the appropria-
te value to store the right digit. After selecting the value press the "PROG" button to save the value and
move to the next digit. Repeat the above procedure procedure to program values for five digits from right
to left. The maximum value for Flow Meter monitoring is 99999 liters. Completion of programming, the
meter will signal with a beep * If no button is pressed for one minute during programming, the procedure
will be terminated and the meter will return to its original state.
After replacing the filter cartridge with a new one, press the RESET button briefly.The display will show
the current state of the counter. Then press the RESET button again for about 5 seconds. The counter
will start monitoring the performance of the new filter.
Operation
Flow Meter automatically turns on and displays the remaining capacity when water flows through the
sensor and automatically turns off after 10 seconds when water is not flowing.
Filter consumption alarm
Flow Meter generates an audible alarm and the digits on the LCD display flash when the remaining
capacity reaches zero or minus. The alarm will be generated every time water flows through the sensor.
Resetting
Press the "RESET" button for three seconds, "RESET" on the LCD will flash twice, and the remaining
capacity is reset to the original programming value