41
Time Lapse Video Cassette Recorder
40
Time Lapse Video Cassette Recorder
If you are also using a Multi View system, use the
following diagrams as a guide to connecting the VCR for
normal or alarm recording.
Connecting to a Multiview System for Normal Recording
ALARM
2
ALARM
3
• SW OUTPUT Terminal
While recording, a pulse signal(DC 5V) is output at the
SW OUT terminal after each recording period. This
terminal is usually connected to the switch input of
devices like a camera switching unit, or a quad
compressor.
1) Low
2) High
• SERIES OUTPUT Terminal
During recording, when the end of the tape is reached,
the output becomes DC 5V .
• SERIES INPUT Terminal
If the input becomes DC 5V for 200 msec or more, the
VCR starts series recording.
• WARNING OUTPUT Terminal
1) “High”
If the error display on the display panel continues to
flash, the output becomes DC 5V. If the STANDBY/ON
(POWER) button is pressed, the emergency mode is
released, then the output becomes 0V.
2) “Low”
If the error display on the display panel continues to
flash, the output becomes 0V. If the STANDBY/ON
(POWER) button is pressed, the emergency mode is
released, then the output becomes DC 5V.