26
PRINTED CIRCUIT BOARD
1. CIRCUIT CHECK PROCEDURE
1. Low Voltage Transformer check
• The low voltage transformer is located on the P.C.B.
• Measuring condition: input voltage : 230V/Frequency : 50Hz
2. Voltage check
• Key check point
• Check method
NOTE :
Each measure point must be measured with GND points.
NOTE :
1. Refer to Circuit Diagram (point 4).
2. Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage.
3. The allowable tolerance of the secondary voltage is within ± 5% of nominal voltage.
NO
CHECK POINT
REMARK
1
IC 1 PIN 2, 21, 30, 34
-5VDC
2
IC 1 PIN 35
3
IC 1 PIN 31 OR 32
T
T:20ms(50Hz)
0V
-5V
T
T:250ns(4MHz)
0V
-5V
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC -5V±0.25V
Replace VL1, EC1
NO LOAD
2
MP2
DC -12V±2.0V
Replace EC2, D10, D11, D12
NO LOAD
Terminal Voltage
4-7
LOAD
AC 25.8 V
NO LOAD
AC 28.4 V