12
5. To remove control panel parts.
(1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
(2) Remove four screws which secure the PCB assembly to control panel.
(3) Disconnect membrane tail from the connector of the PCB assembly.
(4) Detach membrane from the control panel.
(5) Reverse the above steps for reassembly.
REF NO.
PART CODE
PART NAME
DESCRIPTION
Q’TY
REMARK
B01 351857183O
SWITCH
MEMBRANE
KOG-6QDB3A27
1
B02 3516733340
CONTROL-PANEL
HIPS
1
B03 PKMPMSBA4
PCB ASSY.
KOG-6QDB3A27
1
B04
7122401211
SCREW TAPPING
T2S TRS 4X12 MFZN
4
B05
3513702700
LEVER DOOR OPEN
PP
1
B06
3516915210
BUTTON DOOR OPEN
HIPS SG-970, HG-176OH
1
B07
441G430171
SPRING BUTTON
SWP DIA. 0.7
1
CIPANEL ASSEMBLY : PKCPSW140
Содержание KOR-6QDB
Страница 1: ...Service Manual Model KOR 6QDB Microwave Oven Feb 2008 S M No OR6QDB3001...
Страница 24: ...23 WIRING DIAGRAM...
Страница 26: ...25 Measure Point MP1 MP2 GND...