14
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
◆
High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to pre-
vent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall
not exceed 4mW/cm
2
for a fully assembled oven with door normally closed.
<MAGNETRON>
Metallic
gasket
plate
Cooling fin
Filament
terminal
Magnetron antenna