CAUTION
1. Make sure to check the microwave leakage before and after repair of adjustment.
2. Always start measuring of an unknown field to assure safety for operating personnel from microwave energy.
3. Do not place your hands into any suspected microwave radiation field unless the safe density level is known.
4. Care should be taken not to place the eyes in direct line with the source of microwave energy.
5. Slowly approach the unit under test until the radiometer reads an appreciable microwave leakage from the

unit under the test.

2. MICROWAVE RADIATION TEST

PROCEDURE

1. Prepare Microwave Energy Survey Meter, 600cc glass

beaker, and glass thermometer 100°C (212°F).

2. Pour 275cc ± 15cc of tap water initially at 20 ± 5°C (68 ±

9°F) in the 600 cc glass beaker with an inside diameter of
approx. 95 mm(3.7 in.).

3. Place it at the center of the tray and set it in a cavity.

4. Close the door and operate the oven.

5. Measure the leakage by using Microwave Energy Survey

Meter with dual ranges, set to 2450MHz.

1) Measured radiation leakage must not exceed the value

prescribed below. Leakage for a fully assembled oven
with door normally closed must be less than 4mW/cm

2

.

2) When measuring the leakage, always use the 5 cm (2

in.) space cone with probe. Hold the probe
perpendicular to the cabinet and door. Place the space
cone of the probe on the door, cabinet, door seem, door
viewing screen, the exhaust air vents and the suction air
vents.

3) Measuring should be in a counter-clockwise direction at

a rate of 1 in./sec. If the leakage of the cabinet door
seem is unknown, move the probe more slowly.

4) When measuring near a corner of the door, keep the

probe perpendicular to the areas making sure the probe
end at the base of the cone does not get closer than 2
in. from any metal. If it does not, erroneous reading may
result.

Содержание KOR-6L773S

Страница 1: ...73S001 Nov 2011 Caution In this Manual some parts can be changed for improving their performance without notice in the parts list So if you need the latest parts information please refer to PPL Parts...

Страница 2: ...onitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave...

Страница 3: ...ertified oven unit is found to servicing a microwave emission check should be performed prior to servicing the oven a inform the manufacturer importer or assembler b repair the unit at no cost to the...

Страница 4: ...00 W MICROWAVE ENERGY OUTPUT 700 W FREQUENCY 2 450MHz OUTSIDE DIMENSIONS W H D 446 x 270 x 319 mm CAVITY DIMENSIONS W H D 295 x 219 x 303 mm CAVITY VOLUME 20 L NET WEIGHT APPROX 10 Kg TIMER 35min DUAL...

Страница 5: ...4 1 OUTER DIMENSION 446 270 319 EXTERNAL VIEW...

Страница 6: ...always be used for cooking together with the glass cooking tray 7 7 Glass cooking tray Made of special heat resistant glass The tray must always be in proper position before operating Do not cook food...

Страница 7: ...e which if damaged must be repaired with cable of same type Such a cable can be purchased from DAEWOO and must be installed by a qualified person 6 Examine the oven after unpacking for any damage such...

Страница 8: ...neration of microwave power and the operation of cooking timer If you wish to change the time during cooking simply adjust the timer to the desired time 7 When the timer reaches zero a bell will ring...

Страница 9: ...pair work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When replacing or...

Страница 10: ...rd 2 To remove door assembly 1 Remove two screws which secure the stopper hinge top 2 Remove the door assembly from top plate of cavity 3 Reverse the above for reassembly NOTE After replacing the door...

Страница 11: ...nting as 6 Remove the barrier screen outer from the frame door 7 Reverse the above steps for reassembly A00 3511730190 DOOR AS KOR 6L7B3S 1 A01 3512211140 FRAME DOOR HIPS SG 970 HG 1760H 1 A02 3517007...

Страница 12: ...ighten two screws 3 To reduce gap located on part C Loosen the screw on the interlock switch assembly located the top of the oven body Draw the interlock switch assembly inward as possible to engage w...

Страница 13: ...rom the control panel 7 Reverse the above steps for reassembly B00 3513412340 KNOB VPC SG 0760D SG 175 1 B01 3513412350 KNOB SG 0760D SG 175 1 B03 3516740390 CONTROL PANEL HIPS SG 970 HG 1760H 1 B04 3...

Страница 14: ...secure the magnetron 2 Remove the magnetron 3 Reverse the above steps for reassembly NOTE Never install the magnetron without the metallic gasket plate which is packed with each magnetron to prevent...

Страница 15: ...ve wind guide assembly 1 Remove the screw for earthing 2 Remove the noise filter from the wind guide 3 Remove the screw which secure the wind guide assembly 4 Draw forward the wind guide assembly 5 Pu...

Страница 16: ...e button of the primary interlock switch bring it under ON condition 2 Secondary interlock switch and interlock monitor switch When the door is closed the hook pushes the lock lever downward The lock...

Страница 17: ...mer YES If outlet has proper voltage check continuity of power supply cord Replace power supply cord NO Continuity Check continuity of interlock monitor switch with door shut Replace primary secondary...

Страница 18: ...able motor NO If microwave do not oscillate check continuity of filament of magnetron Poor continuity NO Continuity Check continuity filament tap 3 3V of high voltage Replace high Voltage transformer...

Страница 19: ...r the water temperature to attain 20 C 2 C is measured The oven is then switched off and the final water temperature is measured within 60s NOTE 1 The water stirred is before its temperature is measur...

Страница 20: ...in 3 Place it at the center of the tray and set it in a cavity 4 Close the door and operate the oven 5 Measure the leakage by using Microwave Energy Survey Meter with dual ranges set to 2450MHz 1 Meas...

Страница 21: ...e the resistance reading Meter with 6V 9V or higher voltage batteries should be used to check the front back resistance of the diode otherwise an infinite resistance may be read in both directions A n...

Страница 22: ...21 WIRING DIAGRAM...

Страница 23: ...LY Refer to Disassembly and assembly 3 TOTAL ASSEMBLY EXPLODED VIEW AND PARTS LIST F45 F44 F43 F42 F41 F40 A00 B00 F39 F38 F37 F36 F35 F33 F32 F31 F30 F27 F26 F25 F24 F23 F22 F21 F20 F19 F18 F16 F15 F...

Страница 24: ...8302201 CAPACITOR HV 2100VAC 0 98UF 187 75MM 1 F20 3518401000 DIODE HV AS ESJC13 12BX CL01 12 1 F21 3518125500 TRANS HV S1S57A 1 F22 3516003700 SPECIAL SCREW TT3 HEX 4X8 FLG MFZN 4 F23 3510317500 BASE...

Страница 25: ...S M NO OR6L773S001 DAEWOO ELECTRONICS CORP 1 2 Jeo dong 1 il ga Jung gu Seoul Korea C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Nov 2011...

Страница 26: ...N C CR RE EA AT TI IV VE E I IN NC C 6 4 ABOUT THIS MANUAL ABOUT THIS MANUAL M O D E L KOR 6L773S S M 2011 11 22 1 2 3 4 5 MEMO 25p VISION TEL 730 0660 FAX 730 3788 11 11 22 3p 4p 5p 7p 10p 11p 12p 1...

Отзывы: