14
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to pre-
vent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage. It shall
not exceed 4mW/cm
2
for a fully assembled oven with door normally closed.
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring
terminal of the H.V. diode and the capacitor holder.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
◆
High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
<MAGNETRON>
Metallic
gasket
plate
Cooling fin
Filament
terminal
Magnetron antenna
Содержание KOR-6C1B5S
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION...
Страница 25: ...24 WIRING DIAGRAM...
Страница 27: ...26 Measure Point MP1 MP2...
Страница 29: ...28 2 PCB CIRCUIT DIAGRAM...