TROUBLE SHOOTING GUIDE
Following the procedure below to check if the oven is defective or not.
1) Check earthing before trouble checking.
2) Be careful of the high voltage circuit.
3) Discharge the high voltage capacitor.
4) W hen checking the continuity of the switches, fuse or high voltage transform er, disconnect one lead wire from these parts
and check continuity with the AC plug removed. To do otherwise m ay result in a false reading or dam age to your meter.
(TROUBLE 1) O ven does not operate at all : any inputs can not be accepted.
NOTE
W hen electric parts are checked, be sure the pow er cord is not inserted in the w all outlet.
C heck w ire harness, w iring and connection of the term inals and power cord before check the parts listed below.
CHECK
RESULT
CAUSE
REM EDY
F use blow s.
C ontinuity
N o C ontinuity
C ontinuity
0
infinite
Ω
or
A pprox.
150~310
(norm al)
R eplace
N O T E 1
R eplace
N O T E 1
R eplace
R eplace
C heck co ntinuity of
prim ary w inding of low
voltage transform er
M alfunction
of interlock
m on itor
sw itch
D efective low
voltage
transform er
C heck co ntinuity of
interlock m onitor sw itch
w ith door closed
(C O M
N C)
C heck co ntinuity of prim ary
interlock sw itch contact
w ith door partially open
until interlock m onitor switch
contact clos e
(C O M <->N O )
S horted contacts
of prim a ry
interlock sw itch.
F use again
blows
D isconne ct high voltage
fuse and operate the unit
D efective high
voltage transform er
C O N D IT IO N
N o C ontinuity
R eplace
N O T E 1
C heck co ntinuity of both
prim ary and secondary
interlock sw itch w ith door
colosed
M alfunction of
interlock sw itch
N o C ontinuity
C ontinuity
Содержание KOR-63BG0S
Страница 5: ...EXTERNAL VIEW 1 OUTER DIMENSION...
Страница 26: ...WIRING DIAGRAM...
Страница 28: ...PRINTED CIRCUIT BOARD MP1 MP2 Measure Point...
Страница 30: ...PRINTED CIRCUIT BOARD 2 P C B CIRCUIT DIAGRAM...