13
6. To remove high voltage capacitor.
1) Remove a screw which secure the grounding ring
terminal of the H.V. diode and the capacitor hold-
er.
2) Remove the H.V. diode from the capacitor holder.
3) Reverse the above steps for reassembly.
◆
High voltage circuit wiring
7. To remove magnetron.
1) Remove a screw which secure the magnetron.
2) Remove the magnetron.
3) Reverse the above steps for reassembly.
1) Remove the screw which secure the control panel, push up two snap fits and draw forward the control panel assembly.
2) Remove screws which secure the PCB assembly.
3) Disconnect WIRE FLAT from the connector of the PCB assembly.
4) Detach the function buttons and knob from the control panel.
5) Reverse the above steps for reassembly.
NOTE : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave leakage.
It shall not exceed 4mW/cm
2
for a fully assembled oven with door normally closed.