20
10. To remove UV lamp assembly.
1) Remove the screw which secure the UV lamp assembly
to the top-plate.
2) Remove the screw which hold the socket starter *O to the
cover lamp.
3) Remove the socket starter *O from the cover lamp by
pushing up two snap fits.
4) Remove the socket starter *I from the socket starter *O.
5) Remove the terminal starters from the socket starter *I.
6) Remove the starter glow from the socket starter *I.
7) Remove the lamp germicidal from the cover lamp.
8) Remove the socket lamp.
9) Remove the terminal lamp.
10) Reverse the above steps for reasembly.
11. To remove the ballast.
1) Remove two screws holding the ballast.
2) Remove the ballast.
3) Reverse the above steps for reasembly.