Daewoo KOR-1P5CBA Скачать руководство пользователя страница 24

24

3. COMPONENT TEST PROCEDURE

• High voltage is present at the high voltage terminal of the high voltage transformer during any cooking cycle.
• It is neither necessary nor advisable to attempt measurement of the high voltage.
• Before touching any oven components or wiring, always unplug the oven from its power source and discharge the

capacitor.

1. High voltage transformer

1) Remove connections from the transformer terminals and check continuity.
2) Normal readings should be as follows :

Secondary winding ... Approx. 110 

±10% (100 

±10% ÷ KOR-1B4H9A04)

Filament winding ... Approx. 0 

Primary winding ... Approx. 1 

2. High voltage capacitor

1) Check continuity of capacitor with meter on the highest OHM scale.
2) A normal capacitor will show continuity for a short time, and then indicate 10M

once the capacitor charged.

3) A shorted capacitor will show continuous continuity.
4) An open capacitor will show constant 10M

.

5) Resistance between each terminal and chassis should be infinite.

3. High voltage diode

1) Isolate the diode from the circuit by disconnecting the leads.
2) With the ohmmeter set on the highest resistance scale measure the resistance across the diode terminals.

Reverse the meter leads and again observe the resistance reading. Meter with 6V, 9V or higher voltage batteries
should be used to check the front-back resistance of the diode, otherwise an infinite resistance may be read in
both directions. A normal diode's resistance will be infinite in one direction and several hundred k 

in the other

direction.

4. Magnetron

For complete magnetron diagnosis, refer to "Measurement of the Microwave Power Output." Continuity checks can
only indicate and open filament or a shorted magnetron. To diagnose for an open filament or a shorted magnetron,
1) Isolate magnetron from the circuit by disconnecting the leads.
2) A continuity check across magnetron filament terminals should indicate 0.1 

or less.

3) A continuity check between each filament terminal and magnetron case should read open.

5. Fuse

If the fuse in the primary and monitor switch circuit is blown when the door is opened, check the primary and
monitor switch before replacing the blown fuse. In case the fuse is blown by an improper switch operation, replace
the defective switch and fuse at the same time. Replace just the fuse if the switches operate normally.

Содержание KOR-1P5CBA

Страница 1: ...Service Manual Microwave Oven Model KOR 1P5CBA DAEWOO ELECTRONICS CO LTD S M No R1P5CBA001 http svc dwe co kr Sep 2002...

Страница 2: ...n the interlock monitor door seal and microwave generation and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the own...

Страница 3: ...or is opened Do not attempt to defeat them DO NOT ATTEMPT TO SERVICE THIS APPLIANCE UNTIL YOU HAVE READ THIS SERVICE MANUAL 2 FOR SAFE SERVICE PROCEDURES 1 If the oven is operative prior to servicing...

Страница 4: ...NERGY OUTPUT 1100 W MICROWAVE FREQUENCY 2450MHz OUTSIDE DIMENSIONS W X H X D 560X344X483mm 22 0X13 5X19 in CAVITY DIMENSIONS W X H X D 369X221X400mm 14 5X8 7X15 7 in NET WEIGHT APPROX 16 5kg 36 4lbs T...

Страница 5: ...5 EXTERNAL VIEW 560 483 344 1 OUTER DIMENSION...

Страница 6: ...ened while the oven is operating the automatically shut off 4 4 Oven cavity 5 5 Door seal Door seal maintains the microwave energy within the oven cavity and prevents microwave leakage 6 6 Plate tray...

Страница 7: ...ooking data 3 3 Defrost Used to defrost foods for time 4 4 Time Set Pad Used to set the cooking time or cook preprogrammed cooks 5 5 Check Used to check cooking data 6 6 Double Quantity Used to extend...

Страница 8: ...ce This microwave oven requires a current of approximately 14 5 amperes 120Volts 60Hz grounded outlet 1 A short power supply cord is provided to reduce the risks resulting from becoming entangled in o...

Страница 9: ...the oven is plugged in 8 When the STOP CLEAR pad is touched during the oven operation the oven stops cooking and all information retained To erase all information touch the STOP CLEAR pad once more I...

Страница 10: ...nning repair work 2 Warning about the electric charge in the high voltage capacitor For about 30 seconds after the operation stopped and electric charge remains in the high voltage capacitor When repl...

Страница 11: ...ard 2 To remove door assembly 1 Remove two screws which secure the stopper hinge top 2 Remove the door assembly from top plate of cavity 3 Reverse the above for reassembly NOTE After replacing the doo...

Страница 12: ...LR4 POLE 4 10 MFZN 2 A09 3513101200 HOOK POM 1 A10 3515101800 SPRING HOOK PW1 1 A11 3512604800 HANDLE DOOR ABS CR COATING 1 A12 3513586900 LABEL AL1020 T0 5 1 A13 3515204900 STOPPER HINGE T AS KOC 1B0...

Страница 13: ...e top and then push the door to contact the door seal to oven front surface Tighten two screws 2 To reduce gap located on part B Loosen two screws on stopper hinge under and then push the door to cont...

Страница 14: ...1 SCREW TAPPING T2S TRS 4X12 MFZN 4 1 Remove the screw which secure the control panel push up two snap fits and draw forward the control panel assembly 2 Remove four screws which secure the PCB assemb...

Страница 15: ...mally closed Metalic gasket plate Cooling fin Filament terminal MAGNETRON Stub Magnetron antenna 6 To remove high voltage capacitor 1 Remove a screw which secure the grounding ring terminal of the H V...

Страница 16: ...assembly 3 Pull the fan from the motor shaft 4 Remove two screws which secure the motor shaded pole 5 Remove the motor shaded pole 6 Reverse the above steps for reasembly 9 To remove H V transformer...

Страница 17: ...es the lock lever downward The lock lever presses the button of the interlock monitor switch to bring it under NO condition The lock lever presses the button of the secondary interlock switch to bring...

Страница 18: ...nection of the terminals and power cord before check the parts listed below CONDITION CHECK Check continuity of interlock monitor switch with door closed Check continuity of of primary interlock switc...

Страница 19: ...or replace Check D C voltage being supplied to RELAY RY2 coil Defective touch control circuit 0 V Replace Faulty contacts of RELAY RY2 or open relay coil Approx 15 VDC Replace Display do not shown cou...

Страница 20: ...body Continuity Defective magnetron Replace Check resistance of primary and secondary coil of high voltage transformer 0 or Defective high voltage transformer Replace Check continuity of magnetron wi...

Страница 21: ...lay obviously jumps in time while counting down 9 Display counts down noticeable too fast while cooking 10 Display does not show the time of day when clear pad is touched 11 Oven lamp and turntable mo...

Страница 22: ...e vessel the load is immediately placed on the center of the shelf which is in the lowest normal position 4 Microwave power is switched on 5 Heating time should be exactly A seconds Refer to table as...

Страница 23: ...binet door seem door viewing screen the exhaust air vents and the suction air vents 3 Measuring should be in a counter clockwise direction at a rate of 1 in sec If the leakage of the cabinet door seem...

Страница 24: ...he ohmmeter set on the highest resistance scale measure the resistance across the diode terminals Reverse the meter leads and again observe the resistance reading Meter with 6V 9V or higher voltage ba...

Страница 25: ...25 WIRING DIAGRAM...

Страница 26: ...r changes in proportion to fluctuation of power source voltage 3 The allowable tolerance of the secondary voltage is within 5 of nominal voltage NOTE Each measure point must be measured with GND point...

Страница 27: ...27 MP1 MP2 Mesure point...

Страница 28: ...is opened during operation the count down timer does not stop refer to Circuit Diagram point 1 Check method 5 When the digital clock does not operate properly refer to Circuit Diagram point 5 If cloc...

Страница 29: ...29 2 P C B CIRCUIT DIAGRAM...

Страница 30: ...07AV 3519150540 1 18 IC EEPROM IC2 BR9020 W 137N9020W 1 19 PCB MAIN M187 90X90 3514328500 1 20 R ARRAY RA2 3 RGLD4X104J RA 85X104J 2 21 R ARRAY RA1 6P 5 1 8 100K OHM J RA 86X104J 1 22 RESISTOR R8 1 6W...

Страница 31: ...31 EXPLODED VIEW AND PARTS LIST 1 DOOR ASSEMBLY Refer to Disassembly and assembly 2 CONTROL PANEL ASSEMBLY Refer to Disassembly and assembly 3 TOTAL ASSEMBLY...

Страница 32: ...ETRON RM259 STUD 1 F18 3513601500 LAMP BL 125V 25W T25 C5A H18 1 F19 3513816000 LOCK PP 1 F20 3513702100 LEVER SW MICRO POM 1 F21 4415A17352 SW MICRO VP 533A OF SPNO 187 1 F22 4415A66000 SW MICRO VP 5...

Страница 33: ...S M NO R1P5CBA001 DAEWOO ELECTRONICS CO LTD 686 AHYEON DONG MAPO GU SEOUL KOREA C P O BOX 8003 SEOUL KOREA TELEX DWELEC K28177 8 CABLE DAEWOOELEC PRINTED DATE Sep 2002...