16
INTERLOCK MECHANISM AND ADJUSTMENT
The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when
the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.
(1) Primary interlock switch
When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate.
When the door is closed, the hook pushes the button of the microswitch. Then the button of the primary interlock switch
bring it under “ON” condition NO position (NO position).
(2) DOM switch and interlock monitor switch
When the door is closed, the hook pushes the lock lever downward. The hook presses the button of the interlock monitor
switch to bring it under “OFF” condition (NO position) and the lock lever presses the button of the DOM switch to bring it
under “ON” condition (NO position).
(3) Adjustment steps
a) Loosen the mounting screw.
b) Adjust interlock switch assembly position.
Actuation distance of primary and secondary interlock switch shall be adjusted almost 0.7mm.
c) Make sure that lock lever moves smoothly after adjustment is completed.
d) Tighten completely a mounting screw.
ADJUSTMENT :
Interlock monitor switch
When the door is closed, the interlock monitor switch should be opened (NO position) before other switches are closed.
When the door is opened, the interlock monitor switch should be closed (NC position) after other switches are opened.
NOTE :
Microwave emission test should be performed after adjusting interlock mechanism. If the microwave emission exceed
4mW/cm
2
, readjust interlock mechanism.
Содержание KOR-1N4A9W
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION 515 mm 375 mm 304 mm...
Страница 25: ...24 WIRING DIAGRAM...
Страница 27: ...26 Measure Point MP1 GND MP2...
Страница 29: ...28 2 PCB CIRCUIT DIAGRAM...