27
1. CIRCUIT CHECK PROCEDURE
1. Low Voltage Transformer (DMR-602P) check
• The low voltage transformer is located on the P.C.B.
• Measuring condition: input voltage : 120V/Frequency : 60Hz
2. Voltage check
• Key check point
• Check method
PRINTED CIRCUIT BOARD
NO
CHECK POINT
REMARK
1
IC 1 PIN 7,41,42
-5 VDC
2
IC 1 PIN 11
GND
3
IC 1 PIN 23
4
IC 1 PIN 8 OR 9
NOTE :
Each measure point must be measured with GND points.
NOTE :
Secondary side voltage of the low voltage transformer changes in proportion to fluctuation of power source voltage
NOTE :
The allowable tolerance of the secondary voltage is within ± 5% of norminal voltage.
0V
4.3V
5V
0V
Terminal Voltage
4-7
LOAD
AC 12.6 V
NO LOAD
AC 14.7 V
NO
MEASURE POINT
WAVE FORM
REMEDY
REMARK
1
MP1
DC -5V±0.25V
Replace VL1, EC1
NO LOAD
2
MP2
DC -12V±2.0V
Replace EC2, D12, 13, 14
NO LOAD
T:16.7ms(60Hz)
T:250ns(4MHz)
1
2
5
4
3