22
TROUBLE SHOOTING GUIDE
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Outlet has
proper voltage
Fuse does not
blow.
Check continuity of
magnetron
No
Continuity
Defective
magnetron
Replace
Display do not
shown countdown
No
Continuity
Normal
Defective touch
control circuit
Open power
supply cord
Malfunction of
secondar y
interlock switch
Replace
Check continuity of
power supply cord
Replace
Replace
All these switches must be replaced at the same time, please refer to “Interlock Mechanism And Adjustment”.
NOTE
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Turn table
motor, and
oven lamp do
not turn on
No
Continuity
Check continuity of
primary interlock switch
Check continuity of
secondary interlock switch
Check D.C. voltage
being supplied to
RELAY (RY2) coil
Malfunction
of primary
interlock switch
Malfunction
of secondar
interlock switch
Defective
touch control
circuit
Fault
contacts of
RELAY
(RY2) or open
relay coil
Adjust or
Replace
Adjust or
Replace
Replace
Replace
No
Continuity
0 V
Approx
15 VDC
(TROUBLE 2)
Display shows all figures selected, but oven does not start cooking, even thouh desired program and time are
set and start pad is tapped.
Содержание KOR-1A1G0A
Страница 5: ...4 EXTERNAL VIEW 1 OUTER DIMENSION 1 KOR 1A1G H 2 KOR 1A4G H...
Страница 29: ...28 WIRING DIAGRAM 1 KOR 1A1G H 0A KOR 1A4G H 0A...
Страница 34: ...33 PRINTED CIRCUIT BOARD Measure Point...
Страница 36: ...35 2 P C B CIRCUIT DIAGRAM PRINTED CIRCUIT BOARD...
Страница 41: ...40 EXPLODED VIEW AND PARTS LIST 2 KOR 1A4G H F48 F47 F12 F13 F14 F15...