21
The door lock mechanism is a device which has been specially designed to completely eliminate microwave radiation when
the door is opened during operation, and thus to perfectly prevent the danger resulting from the leakage of microwave.
(3) Adjustment steps
1) Loosen the mounting screw.
2) Adjust interlock switch assembly position.
3) Make sure that lock lever moves smoothly after adjustment is completed.
4) Tighten completely the mounting screw.
(1) Primary interlock switch
When the door is closed, the hook locks the oven door. If the door is not closed properly, the oven will not operate. When
the door is closed, the hook
pushes the button of the microswitch.
Then the button of the primary interlock switch bring it under “ON” condition.
(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the lock lever downward. The lock lever presses the button of the interlock
monitor switch to bring it under “OFF” condition and presses the button of the secondary interlock switch to bring it under
“ON” condition.
ADJUSTMENT :
Interlock monitor switch
When the door is closed, the interlock monitor switch should be changed(NO condition) before other switches are closed.
When the door is opened, the interlock monitor switch should be changed(NC condition) after other switches are opened.
NOTE :
Microwave emission test should be performed after adjusting interlock mechanism.
If the microwave smission exceed 4mW/cm
2
, readjust interlock mechanism.
INTERLOCK MECHANISM AND ADJUSTMENT
Содержание KOG-6C075S
Страница 28: ...27 WIRING DIAGRAM...