21
CONDITION
CHECK
Check continuity of high
voltage fuse
RESULT
No
Continuity
Check continuity if high
voltage capacitor terminals
with wires removed
Replace high voltage fuse
Continuity
CAUSE
Defective high
voltage
transformer
REMEDY
Replace
No
microwave
oscillation
Check continuity of high voltage
rectifier in forward and backward
direction with DC megger
Continuity in
backward
direction
Defective high
voltage rectifier
Replace
Connect megger leads to
magnetron terminal and
magnetron body
Continuity
Defective
magnetron
Replace
Check resistance of primary and
secondary coil of high voltage
transformer
0
Ω
or
∞
Defective high
voltage
transformer
Replace
Check continuity of magnetron
with wires removed
No
Continuity
Defective
magnetron
Replace
Check continuity of filament
terminal of high voltage
transformer
No
Continuity
Defective high
voltage
transformer
Replace
Check D.C. voltage being
supplied to RELAY (RY1) coil
0 V
Defective touch
control circuit
Replace
Approx
15 VDC
Faulty
contacts or
RELAY (RY1)
or open
relay coil
Replace
(TROUBLE 3) No microwave oscillation even though fan motor rotates.
Содержание KOG-37DP0S
Страница 1: ...Service Manual Microwave Oven Model KOG 37DP0S KOG 37FP0S DAEWOO ELECTRONICS CO LTD S M No G37DP0S001 ...
Страница 5: ...4 1 OUTER DIMENSION 1 KOG 37DP0S 2 KOG 37FP0S EXTERNAL VIEWS ...
Страница 27: ...26 WIRING DIAGRAM ...
Страница 29: ...28 Mesurement point MP1 MP2 ...
Страница 31: ...30 2 P C B CIRCUIT DIAGRAM ...