(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the push lever down ward, and push lever presses the
button of the interlock monitor swich to bring it under “off”, condition and presses the button of the
secondary interlock switch to bring it under “on”, condition.
Adjustment 2.
Interock monitor switch
When the door is closed, the interlock monitor switch should be opend before other switches close.
When the door is closed, the interlock monitor switch should be closed after other switches open.
Secondary interlock switch
The movent of the switch button should exceed 1.2mm measured at the top of the button.
(3) Adjustment steps
a) Loosen the two mounting screws.
b) Adjust interliock switch assembly position.
c) Confirm the gap (1.2mm) described above.
d) Make sure that push lever moves smoothly adjustments is completed.
e) Completly tighten the two mounting screws.
(4) Interlock switch resplacement
Whenever safety interlock switches are replaced:
1) Refer to the following diagram.
2) Check the connection of monitor switch after replacement.
3) Perform the electrical continuity check of interlock switches and microwave emission test men
tioned in this manual.
SYMBOL
RD
BL
BK
WH
GN
COLOR
RED
BLUE
BLACK
WHITE
GREEN
19
NOTE:
Microwave emission test should be performed after adjusting interlock machanism. If the
microwave emission exceed 4mW/cm
2
, readjust interlock mechanism.
Содержание KOG-261M
Страница 1: ...Service Manual Microwave Oven KOG 261M KOG 262M KOG 281M KOG 282M DAEWOO ELECTRONICS CO LTD...
Страница 24: ...23...
Страница 37: ...36 WIRING DIAGRAM...
Страница 45: ...45 Fig 6 Measurement Point...
Страница 48: ...2 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode 48...
Страница 49: ...49 3 PRINTED CIRCUITS BOARD...
Страница 50: ...50 4 P C B CIRCUIT DIAGRAM...
Страница 54: ...54...