(2) Monitor interlock switch
When the door is closed, the hook pushes the lever forward, and pushes the Latch Lever downward the lever press the
button of the interlock monitor switch to bring it under ‘OFF’ condition. The latch Lever press the button on the secondary
interlock switch to bring it under ‘ON’ condition.
- Adjustment
Interlock monitor switch
When the door is closed, the monitor switch should be opened before other switches close.
When the door is opened, the monitor switch should be closed after other switches open.
Adjustment steps :
a) Loosen the two mounting screws.
b) Adjust the interlock switch assembly position.
c) Make sure that the latch lever moves smoothly after adjustment is completed.
d) Completely tighten the two mounting screws.