18
9. TO REMOVE H.V.TRANSFORMER
1) Remove four screws holding the H.V.transformer.
2) Remove the H.V.transformer.
3) Reverse the above steps for reassembly.
8. TO REMOVE BLOWER MOTOR
1) Remove a screw which secure the cover motor blower.
2) Remove a screw which secure the blower motor.
3) Remove the cover motor blower.
4) Remove the wire which connecting the blower motor
5) Push a latch of blower motor and draw backward
6) Reverse the above steps for reassembly.
COVER MOTOR BLOWER
BLOWER MOTOR
LATCH
Содержание KOC-1C0K5SV1