2. FUNCTIONS
2-3. Defrost Mode
D. Flow chart of How to Start Defrost Mode
※
A.C.R.T. : Accumulated Compessor Run Times
※
R.R.O.C. : Running Rate of Compressor
※
RT: Ambient temperature
Start
Yes
No
A.C.R.T.= 6,8,10,12hours
No
Yes
Any Error
No
Yes
R.R.O.C.(per 2hrs of A.C.R.T.)≥90%
No
Yes
Accumulated Door Open Time≥2min.
No
Yes
RT≥39.1
℃
No
Yes
A.C.R.T.≥ 14hours
Defrost Mode Start
End