28
NO.
Control Control
Contents Remark
Function Objects
14 Low COMP.
cooling R-fan
prevent
function
15 COMP. COMP.
restart
prevent
16 Error LED
display
1. The low cooling prevention function will be operating if the
temperature of R1-sensor or R2-sensor goes above 6˚C.
2. Time chart
3. R1 and R2-sensor detects the low cooling prevention function,
but only R1-sensor returns the normal function.
1. The COMP. can not be on within 6 min. after COMP. off.
2. During Pre-cool step in defrost mode. 6 min. delay is
unavailable.
1. Press the quick freezing button 3 times when press the quick
fridge and fridge temperature button.
2. If press the freezer temperature button, then stage changed
like follow.
R1-sensor temperature
➝
D-sensor temperature
➝
F-sensor
temperature
➝
Error code
3. Auto return to the normal time is 8 min. without pressing the
freezer temperature button.
low cooling
detection
temp. (6˚C)
R-FAN ON
COMP
C-FAN
R-FAN
R-FAN OFF
The COMP turns off by R1-S
: ON
: OFF
FUZZY
QUICK
FRIDGE.
HOUR
FRIDGE
TEMP.
QUICK
FREEZING
FREEZER
TEMP.
MIN
TIME
SET
FRZ.
FRESH
CLEAN
E.F 1 2 3 F F
4 5 5 4 3 2 1 E. F
Q. Q.
REF.