17
Input
Control Object
Contents
Remark
4. Flow Chart of Control of Load Confrontation Mode
Start
End
Initial 240min. passed?
Control Mode?
Avoidance Condition of
Load Confrontatior?
Door Open for more
than 30 seconds?
F-Sensor ON+
5 degree?
Deciding Freezer
Over-load
Deciding Freezer Over Load
Deciding Refrigerator Over Load
Termination of
Frezer Over-load Mode
Termination of
Refrigerator
Over-load Mode
Deciding Refrigerator
Over-load
R-Sensor ON+
5 degree?
Over-load Mode?
Over-load Mode
Control
Normal Mode Control
F Load Con. Time;
20 minutes passed?
F-Sensor OFF Point?
R Load Con. Time;
20 minutes paees?
R-Sensor OFF Rpint?
Y
N
N
N
N
Y
N
Y
Y
Y
Y
Y
Y
Normal Mode
Silent Mode
Deciding Fan RPM
Normal Over Load
F Fan
11V
14V
R Fan
11V
14V
C Fan
11V
11V
Deciding Fan RPM
Normal Over Load
F Fan
8V
11V
R Fan
8V
11V
C Fan
8V
8V
N
N
N
N
Y
Y
N
Содержание FR-631ND
Страница 34: ...33 4 DIAGRAM 4 1 WIRING DIAGRAM ...
Страница 35: ...34 4 2 CIRCUIT DIAGRAM ...
Страница 38: ...37 5 EXPLODED VIEW AND PARTS LIST 5 1 TOTAL EXPLODED VIEW ...