21
2) Function table
NO.
Control
Control
Contents
Remark
Function
Objects
1
Quick
COMP.
Freezing
Fan
LED
2
Freezer tem-
COMP.
perature control
Fan
3
Prevent COMP.
COMP.
restarting
Fan
4
Warm &
LED
normal
TEMP.
LED
5
Defrost
COMP.
Fan
Heater
1. If press the quick freezing switch, then illuminates quick
freezing LED and starts quick freezing. (If press again, then
stops quick freezing)
2. COMP. and Fan operate for 90 min continuously.
3. After 90 min. F-sensor checks the temperature. If it is COMP.
on temperature, it continues quick freezing until it reaches
COMP off temperature.
4. If it becomes auto defrosting time during quick freezing,
defrosting starts from Pre-cool after finishing quick freezing.
5. If quick freezing switch is turn on during defrosting Pre-cool,
defrosting starts from Pre-cool after finishing quick freezing.
But if COMP. has been operating for more than 40 min., the
Pre-cool will be omitted.
6. If quick freezing switch is turned on during Defrosting Heater
on or Fan delay, it performs quick freezing just after finishing
defrosting. But the quick freezing LED comes on immediately.
1. COMP. on/off temperature is controlled by F-sensor.
2. Usually COMP. and the fan operates simultaneously.
1. Restarting in 6 min. after COMP. off.
1. If F-sensor detects temperature over -5ûC, warm temperature
LED is on.
2. During defrosting, the normal temperature LED is always on
and F-sensor detects the temperature after finishing defrosting.
3. In quick freezing, warm temperature LED and normal
temperature LED are off.
PRE-COOL
Defrosting
Fan & COMP.
delay
COMP.
Fan
D-heater
Prior range
quick freezing
defrosting
Содержание FR-440M
Страница 16: ...10 EXPLODED VIEW AND PARTS LIST 14 1 FR 440 1 Exploded views ...
Страница 19: ...17 2 FR 440P 1 Explode view ...